header
Image from OpenLibrary

Clinical predictors of defibrillation thresholds measured intraoperatively during implantation of implantable cardioverter defibrillators / Ahmed Abdellatif Hussein ; Supervised Medhat Elrefai , John Camm , Yasser Baghdady

By: Contributor(s): Material type: TextTextLanguage: eng Publication details: Cairo : Ahmed Abdellatif Hussein , 2010Description: 160P. : charts , facsimiles ; 25cmOther title:
  • المنبئات الإكلينيكية لحدود إنهاء الرجف البطينى المقاس أثناء زرع جهاز إعادة نظم القلب الكهربائى [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Cardiology Summary: Defibrillation Threshold Testing (DFT ) testing is a lengthy potentially painful and a hazardous process . Little information is available concerning the identification of patients with high DFT who undergo ICD implantation with transvenous leads . Patints with predicted low DFT may be eligible for abbreviated ICD testing but high - risk patients who require multiple shocks may require general anesthesia for patient comfort
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.04.Ph.D.2010.Ah.C (Browse shelf(Opens below)) Not for loan 01010110053145000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.04.Ph.D.2010.Ah.C (Browse shelf(Opens below)) 53145.CD Not for loan 01020110053145000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.11.04.Ph.D.2009.No.C Correlation between clinical parameters , blood pressure dipping , highly sensitive CRP plasma level and carotid intima- media thickness in patients with obstructive sleep apnea / Cai01.11.04.Ph.D.2010.Ab.L Laser trnsseptal puncture : A novel approach, guided by X - Ray fluoroscopy , real - time MRI and X - Ray fused with MRI ( XFM ) / Cai01.11.04.Ph.D.2010.Ab.L Laser trnsseptal puncture : A novel approach, guided by X - Ray fluoroscopy , real - time MRI and X - Ray fused with MRI ( XFM ) / Cai01.11.04.Ph.D.2010.Ah.C Clinical predictors of defibrillation thresholds measured intraoperatively during implantation of implantable cardioverter defibrillators / Cai01.11.04.Ph.D.2010.Ah.C Clinical predictors of defibrillation thresholds measured intraoperatively during implantation of implantable cardioverter defibrillators / Cai01.11.04.Ph.D.2010.Ah.C Clinical predictors for defibrillation thresholds measured intraoperatively during implantation of implantable cardioverter defibrillators / Cai01.11.04.Ph.D.2010.Ah.C Clinical predictors for defibrillation thresholds measured intraoperatively during implantation of implantable cardioverter defibrillators /

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Cardiology

Defibrillation Threshold Testing (DFT ) testing is a lengthy potentially painful and a hazardous process . Little information is available concerning the identification of patients with high DFT who undergo ICD implantation with transvenous leads . Patints with predicted low DFT may be eligible for abbreviated ICD testing but high - risk patients who require multiple shocks may require general anesthesia for patient comfort

Issued also as CD

There are no comments on this title.

to post a comment.