header
Local cover image
Local cover image
Image from OpenLibrary

Evaluation the closed sinus lift technique with using different grafting materials with simultaneous implantation / Ahmed Abdelwahab Amin Elamrety ; Supervised Mounier Ahmed Shaker , Kadry Nasr Geissa

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ahmed Abdelwahab Amin Elamrety , 2010Description: 107 Leaves : charts , facsimiles ; 25cmOther title:
  • تقييم تقنية رفع الجيب الانفى باستخدام مواد الترقيع المختلفة فى نفس الوقت مع غرس الاسنان [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral Surgery Summary: The aim of the present study is to evaluate the closed sinus lift technique with using hydroxy apatite Fisiograft (gel composition + powder composition) as grafting materials with simultaneous implantation . The current study comprised 12 fixtures screwplant of spectra in 11 patients . The implants were inserted instead of upper first molar in 8 cases and instead of second molar in 4 cases . The fixtures diameter was 4.7 mm and length was 10 m for all cases . Density changes in the peri- implant bone was determined by drawing 2 straight lines parallel to the implant and 2 mm away from the implant and one the mesial aspect and the other line on the distal aspect
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.11.M.Sc.2010.Ah.E (Browse shelf(Opens below)) Not for loan 01010110055393000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.11.M.Sc.2010.Ah.E (Browse shelf(Opens below)) 55393.CD Not for loan 01020110055393000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral Surgery

The aim of the present study is to evaluate the closed sinus lift technique with using hydroxy apatite Fisiograft (gel composition + powder composition) as grafting materials with simultaneous implantation . The current study comprised 12 fixtures screwplant of spectra in 11 patients . The implants were inserted instead of upper first molar in 8 cases and instead of second molar in 4 cases . The fixtures diameter was 4.7 mm and length was 10 m for all cases . Density changes in the peri- implant bone was determined by drawing 2 straight lines parallel to the implant and 2 mm away from the implant and one the mesial aspect and the other line on the distal aspect

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image