Power factor correction in an industrial factory in the existence of rich harmonics / Elham Mohamed Darwish ; Supervised Ahdab M. K Elmorshedy
Material type: TextLanguage: English Publication details: Cairo : Elham Mohamed Darwish , 2012Description: 159P. : charts , facsimiles ; 30cmOther title:- تحسين معامل القدرة لمصنع فى وجود توافقيات عالية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2012.El.P (Browse shelf(Opens below)) | Not for loan | 01010110059960000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2012.El.P (Browse shelf(Opens below)) | 59960.CD | Not for loan | 01020110059960000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.07.M.Sc.2012.De.P Prediction of H. V. T. L . insulators flashover / | Cai01.13.07.M.Sc.2012.De.P Prediction of H. V. T. L . insulators flashover / | Cai01.13.07.M.Sc.2012.El.P Power factor correction in an industrial factory in the existence of rich harmonics / | Cai01.13.07.M.Sc.2012.El.P Power factor correction in an industrial factory in the existence of rich harmonics / | Cai01.13.07.M.Sc.2012.Em.I Improvement of power system harmonics resulted from using the DC-converter loads and electric ARC furnaces in distribution networks / | Cai01.13.07.M.Sc.2012.Em.I Improvement of power system harmonics resulted from using the DC-converter loads and electric ARC furnaces in distribution networks / | Cai01.13.07.M.Sc.2012.Fa.M Minimization of total voltage harmonic distortion for DC drive loads / |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
The main goal of this thesis is to study the power factor correction of industrial loads in presence of rich harmonics by using drtuned filters in factory at 6 {u036D} {u036A} October city to a void the penalty and to obtain bonus due to over correcting . This study is split into two parts the first part is the real measurements using megger PA-9 plus device to record PF the second part is simulation of a case study by ETAP software to calculate PF and (1,VTHD)