Improvement of power system harmonics resulted from using the DC-converter loads and electric ARC furnaces in distribution networks / Emad Eldin Farouk Mahmoud Sharouda ; Supervised Husien Abdulkhalik Attia , Mohamed Mamdouh Abdulaziz
Material type: TextLanguage: English Publication details: Cairo : Emad Eldin Farouk Mahmoud Sharouda , 2012Description: 108 P. : plans ; 30cmOther title:- تحسين مستوى التوافقيات الناشئة من استخدام أحمال محول التيار الثابت و أفران القوس الكهربى في شبكات التوزيع الكهربية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2012.Em.I (Browse shelf(Opens below)) | Not for loan | 01010110060447000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2012.Em.I (Browse shelf(Opens below)) | 60447.CD | Not for loan | 01020110060447000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.07.M.Sc.2012.De.P Prediction of H. V. T. L . insulators flashover / | Cai01.13.07.M.Sc.2012.El.P Power factor correction in an industrial factory in the existence of rich harmonics / | Cai01.13.07.M.Sc.2012.El.P Power factor correction in an industrial factory in the existence of rich harmonics / | Cai01.13.07.M.Sc.2012.Em.I Improvement of power system harmonics resulted from using the DC-converter loads and electric ARC furnaces in distribution networks / | Cai01.13.07.M.Sc.2012.Em.I Improvement of power system harmonics resulted from using the DC-converter loads and electric ARC furnaces in distribution networks / | Cai01.13.07.M.Sc.2012.Fa.M Minimization of total voltage harmonic distortion for DC drive loads / | Cai01.13.07.M.Sc.2012.Fa.M Minimization of total voltage harmonic distortion for DC drive loads / |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
Power system harmonics are considered the major effects on reducing power quality level. So, we must improve these harmonics to acceptable level according to IEEE Std. 519-1992. Usage of some of non-linear loads can produce harmonics in power system networks. In this thesis we have studied two types of non-linear loads which can produce harmonics
Issued also as CD
There are no comments on this title.