header
Local cover image
Local cover image
Image from OpenLibrary

Effect of surface modification on ceramometal bond strength of A titanium based system / Ramy Gaber Mohamed Abdelkareem ; Supervised Eman Mohamed Anwar Hussein , Rasha Nabil Mohamed Sami

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ramy Gaber Mohamed Abdelkareem , 2012Description: 84 Leaves : charts , facsimiles ; 30cmOther title:
  • تأثير التعديل السطحى على قوة الربط السيراميكية المعدنية بنظام قائم على التيتانيوم [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: The aim of the present study was to evaluate the effect of surface modification on ceramometal bond strength of a titanium based system. Results The use of HCL acid solutions did not improve titanium - ceramic shear bond strength values when compared to the control group that represented the manufacturer 's protocol. The use of HNO3 -HF acid solution improved titanium - ceramic shear bond strength values when compared to the control and HCL group
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2012.Ra.E (Browse shelf(Opens below)) Not for loan 01010110063176000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2012.Ra.E (Browse shelf(Opens below)) 63176.CD Not for loan 01020110063176000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

The aim of the present study was to evaluate the effect of surface modification on ceramometal bond strength of a titanium based system. Results The use of HCL acid solutions did not improve titanium - ceramic shear bond strength values when compared to the control group that represented the manufacturer 's protocol. The use of HNO3 -HF acid solution improved titanium - ceramic shear bond strength values when compared to the control and HCL group

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image