header
Local cover image
Local cover image
Image from OpenLibrary

Influence of cantilever extension on bone level change and screw loosening at implant supported fixed parial denture using early loading protocol / Rami Mohammed Galal ; Supervised jylan Foad Elguindy , Ahmed Nagiub Mohammed , Magdah Ismail Ramzy

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Rami Mohammed Galal , 2013Description: 136 Leaves : facsimiles ; 30cmOther title:
  • تأثير المسافة المعلقة على التغير فى مستوى العظم وتخلخل مسمار التثبيت فى التركيبات الجزئية المدعومة بالغرسات بإستخدام بروتوكول التحميل المبكر [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Oral and dental Medicine - Department of Prosthodontics Summary: This study was conducted to investigate the effect of different cantilever extensions on marginal bone loss around implant supporting fixed partial denture. A total number of fifeen implant supported fixed partions were used. there were three gruops, one with 4 mm distal cantilever extension , the other with 6 mm and the last with 8 mm cantilever extension distally
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2013.Ra.I (Browse shelf(Opens below)) Not for loan 01010110063175000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2013.Ra.I (Browse shelf(Opens below)) 63175.CD Not for loan 01020110063175000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.Ph.D.2013.Mo.E The effect of silicone rubber housing versus metal housing of ball and socket attachment on the muscles activity of mandibular implant retained overdentures : A randomized clinical trial / Cai01.09.09.Ph.D.2013.Na.B Biting force and changes of salivery immunoglobulin with locator root attachments retained mandibular overdenture fabricated of two recent denture base materials / Cai01.09.09.Ph.D.2013.Na.B Biting force and changes of salivery immunoglobulin with locator root attachments retained mandibular overdenture fabricated of two recent denture base materials / Cai01.09.09.Ph.D.2013.Ra.I Influence of cantilever extension on bone level change and screw loosening at implant supported fixed parial denture using early loading protocol / Cai01.09.09.Ph.D.2013.Ra.I Influence of cantilever extension on bone level change and screw loosening at implant supported fixed parial denture using early loading protocol / Cai01.09.09.Ph.D.2013.Re.E Effect of different preparation designs on the vertical marginal gap distance : Fracture resistance and retention of different CAD/CAM ceramic endocrowns / Cai01.09.09.Ph.D.2013.Re.E Effect of different preparation designs on the vertical marginal gap distance : Fracture resistance and retention of different CAD/CAM ceramic endocrowns /

Thesis (Ph.D.) - Cairo University - Faculty of Oral and dental Medicine - Department of Prosthodontics

This study was conducted to investigate the effect of different cantilever extensions on marginal bone loss around implant supporting fixed partial denture. A total number of fifeen implant supported fixed partions were used. there were three gruops, one with 4 mm distal cantilever extension , the other with 6 mm and the last with 8 mm cantilever extension distally

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image