header
Local cover image
Local cover image
Image from OpenLibrary

Ampacity of underground distribution electrical power cables / Noha Mohammed Saber Amin ; Supervised Osama Elsayed Gouda

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Noha Mohammed Saber Amin , 2014Description: 145 P. : charts ; 30cmOther title:
  • السعة التيارية للكابالات األارضية لتوزيع القوى الكهربائية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machine Summary: The maximum current carrying capacity of the power cables which buried in the ground is affected by many factors such as moisture content, soil thermal resistivity of surrounding soil, ambient temperature, depth of laying of cable and the formation of dry zone around the power and distribution cables, which lead to increase of the thermal resistivity and decrease in the maximum current carrying capacity. Under loading condition, heat generated from the cables raises the temperature of the surrounding soils and leads to thermal instability then formation of the dry zone. The dry zone formation affects the cables current carrying capacity and the cables insulation such as decrease in the cable life-time. In this thesis 12 types of soils are tested (sand, lime, 3 mixtures of sand and lime, clay, 3 mixtures of sand and clay, mixtures of sand & lime & clay, pure peat-moss and vermiculite materials). It is noticed that some types of soils formed the dry zone faster than others. The aim of this thesis is to determine the best type of the soil that can be used as backfill-material to reduce the dry zone effect on the cables. Also calculate the de-rating factor for the formation of dry zone for different types of soils. The velocity of dry band formation around different types of distribution cables and its radius are calculated by the aid of experimental results that obtained from the tests carried out on different soil types which are mentioned before
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2014.No.A (Browse shelf(Opens below)) Not for loan 01010110064834000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2014.No.A (Browse shelf(Opens below)) 64834.CD Not for loan 01020110064834000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machine

The maximum current carrying capacity of the power cables which buried in the ground is affected by many factors such as moisture content, soil thermal resistivity of surrounding soil, ambient temperature, depth of laying of cable and the formation of dry zone around the power and distribution cables, which lead to increase of the thermal resistivity and decrease in the maximum current carrying capacity. Under loading condition, heat generated from the cables raises the temperature of the surrounding soils and leads to thermal instability then formation of the dry zone. The dry zone formation affects the cables current carrying capacity and the cables insulation such as decrease in the cable life-time. In this thesis 12 types of soils are tested (sand, lime, 3 mixtures of sand and lime, clay, 3 mixtures of sand and clay, mixtures of sand & lime & clay, pure peat-moss and vermiculite materials). It is noticed that some types of soils formed the dry zone faster than others. The aim of this thesis is to determine the best type of the soil that can be used as backfill-material to reduce the dry zone effect on the cables. Also calculate the de-rating factor for the formation of dry zone for different types of soils. The velocity of dry band formation around different types of distribution cables and its radius are calculated by the aid of experimental results that obtained from the tests carried out on different soil types which are mentioned before

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image