Dynamic test of a 1/8 scale two story lightly reinforced concrete building / Khaled Sherif Abdelrahman Mohamed ; Supervised Adel Galal Elattar , Abdelhamid Ibrahim Zaghw

بواسطة: المساهم: نوع المادة : نصاللغة: الإنجليزية تفاصيل النشر: Cairo : Khaled Sherif Abdelrahman Mohamed , 2014الوصف: 111 P. : charts , facsimiles ; 30cmعنوان آخر:
  • الاختبارالديناميكى لمبنى خرسانى بمقياس 1\8 ذو تسليح خفيف مكون من طابقين [عنوان مضاف عنوان الصفحة]
الموضوع: موارد على الإنترنت: Available additional physical forms:
  • Issued also as CD
ملاحظة الأطروحة: Thesis (M.Sc.) - Cairo University - Faculty of Engineering- Department of Civil Engineering ملخص: A 1/8 scale reinforced concrete building model was tested on shaking table. The reinforcement details were based on typical elements subjected to vertical loads only according to (ECP 203). The model was tested using the time compressed Aqaba 1995 at different amplitudes. Free vibration test were performed before and after each seismic test to study the changes in the model building properties. Test results indicated that the non seismic reinforcement details may form a potential source of damage, and it was found experimentally that they did not lead to collapse or a complete failure mechanism
وسوم من هذه المكتبة: لا توجد وسوم لهذا العنوان في هذه المكتبة. قم بتسجيل الدخول لإضافة الوسوم.
التقييم باستخدام النجوم
    متوسط التقييم: 0.0 (0 صوتًا)
المقتنيات
نوع المادة المكتبة الحالية المكتبة الرئيسية رقم الاستدعاء رقم النسخة حالة الباركود
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2014.Kh.D (استعراض الرف(يفتح أدناه)) لا تعار 01010110064835000
CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2014.Kh.D (استعراض الرف(يفتح أدناه)) 64835.CD لا تعار 01020110064835000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering- Department of Civil Engineering

A 1/8 scale reinforced concrete building model was tested on shaking table. The reinforcement details were based on typical elements subjected to vertical loads only according to (ECP 203). The model was tested using the time compressed Aqaba 1995 at different amplitudes. Free vibration test were performed before and after each seismic test to study the changes in the model building properties. Test results indicated that the non seismic reinforcement details may form a potential source of damage, and it was found experimentally that they did not lead to collapse or a complete failure mechanism

Issued also as CD

لا توجد تعليقات على هذا العنوان.

اضغط على الصورة لمشاهدتها في عارض الصور

صورة الغلاف المحلية
شارك
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library