header
Local cover image
Local cover image
Image from OpenLibrary

Exercise capacity response to acapella device in patients with chronic suppurative lung diseases : / Tarek Aboelmaged Mohammed ; Supervised Akram Abdelaziz , Nesreen Ghareeb Mohamed Elnahas , Sabah Ahmed Mohamed

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Tarek Aboelmaged Mohammed , 2014Description: 139 P. : charts , facsimiles ; 25cmOther title:
  • إستجابة قدرة التمارين لجهاز الأكابيلا لمرضى التقيح الرئوى المزمن [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Physical Therapy for Cardiopaulmonarty and Geriatrics Disorders Summary: Purpose: To investigate the response of exercise capacity to acapella device in patients with chronic suppurative lung diseases (CSLD). Results: Statistical analysis revealed a significant improvement of all blood gases and exercise capacity with study group when compared with control group. The percentage of decrease of PaCo2 was17.7 %, Borg scale was 37.08%,also for systolic blood pressure was 6.28% and that of diastolic blood pressure was 5.94% and the percentage of increase of Pao2 was 22.32% , SaO2 was 10.72% and that of the six minute walk distance was 24.33% for the study and for the control group the percentage of decrease of PaCo2 was 4.64%, Borg scale was 17.33% , also for systolic blood pressure was 4.29% and that of diastolic blood pressure was 4.23%, the percentage of increase of Pao2 was 5.36% , SaO2 was 3.19% ,and that of the six minute walk distance was 11.88%
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.02.M.Sc.2014.Ta.E (Browse shelf(Opens below)) Not for loan 01010110065070000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.02.M.Sc.2014.Ta.E (Browse shelf(Opens below)) 65070.CD Not for loan 01020110065070000

Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Physical Therapy for Cardiopaulmonarty and Geriatrics Disorders

Purpose: To investigate the response of exercise capacity to acapella device in patients with chronic suppurative lung diseases (CSLD). Results: Statistical analysis revealed a significant improvement of all blood gases and exercise capacity with study group when compared with control group. The percentage of decrease of PaCo2 was17.7 %, Borg scale was 37.08%,also for systolic blood pressure was 6.28% and that of diastolic blood pressure was 5.94% and the percentage of increase of Pao2 was 22.32% , SaO2 was 10.72% and that of the six minute walk distance was 24.33% for the study and for the control group the percentage of decrease of PaCo2 was 4.64%, Borg scale was 17.33% , also for systolic blood pressure was 4.29% and that of diastolic blood pressure was 4.23%, the percentage of increase of Pao2 was 5.36% , SaO2 was 3.19% ,and that of the six minute walk distance was 11.88%

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image