Effect of storage and cyclic loading on the fracture resistance of new provisional prosthetic system / Manal Abulgasem Ahmed Sheria ; Supervised Ashraf Hassan Mokhtar , Eman Mohammad Anwar

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Manal Abulgasem Ahmed Sheria , 2013Description: 91 Leaves : charts , facsimiles ; 30cmOther title:
  • تأثير التخزين والتحميل الدورى على مقاومه الكسر لنظام تعويضى مؤقت جديد [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: Aim of the study: The aim of present study was to evaluated the effect of storage in artificial saliva and cyclic loading on fracture resistance of new CAD/CAM provisional prosthetic material in comparison with two currently used provisional prosthetic materials namely Protemp4 and VITA CAD- temp . Results: There was no statistically significant difference between control and cyclic loading; Stored material showed the statistically significantly lowest mean fracture resistance. As regards Control as well as Cyclic loading: Protemp4 showed statistically significantly higher mean fracture resistance than VITA CAD-temp. As regards stored material: Protemp 4 showed statistically significantly higher mean fracture resistance than VITA CAD-temp
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2013.Ma.E (Browse shelf(Opens below)) Not for loan 01010110065901000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2013.Ma.E (Browse shelf(Opens below)) 65901.CD Not for loan 01020110065901000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

Aim of the study: The aim of present study was to evaluated the effect of storage in artificial saliva and cyclic loading on fracture resistance of new CAD/CAM provisional prosthetic material in comparison with two currently used provisional prosthetic materials namely Protemp4 and VITA CAD- temp . Results: There was no statistically significant difference between control and cyclic loading; Stored material showed the statistically significantly lowest mean fracture resistance. As regards Control as well as Cyclic loading: Protemp4 showed statistically significantly higher mean fracture resistance than VITA CAD-temp. As regards stored material: Protemp 4 showed statistically significantly higher mean fracture resistance than VITA CAD-temp