Numerical simulation for thermal comfort using conditioned air through mixing and personalized ventilation systems in field environmental chamber (FEC) / Hossam Awad El-Maghraby Abdelaal ; Supervised Essam E. Khalil Hassan Khalil , Esmail Mohamed Ali El-Bialy , Omar Ahmed Huzayyin

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Hossam Awad Elmaghraby Abdelaal , 2014Description: 212 P. : charts , plans , facsimiles ; 30cmOther title:
  • نمذجة عددية للراحة الحرارية باستخدام الهواء المكيف الصادر من نظامي التهوية بالخلط و التهوية الشخصية في غرفة إختبار بيئي [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering Summary: Thermal comfort within a Field Environmental Chamber (FEC) office mockup was numerically simulated throughout the current study. The goal of this research was to determine the best scenario to provide conditioned supply of air and distribute it inside an office room by using MV and PV systems to create the best status of thermal comfort for a sitting occupant who is typing in front of a computer screen. Thermal comfort mathematical indices like the Predicted Mean Vote (PMV) and the Predicted Percentage of Dissatisfied (PPD) were implemented
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.11.M.Sc.2014.Ho.N (Browse shelf(Opens below)) Not for loan 01010110065915000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.11.M.Sc.2014.Ho.N (Browse shelf(Opens below)) 65915.CD Not for loan 01020110065915000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering

Thermal comfort within a Field Environmental Chamber (FEC) office mockup was numerically simulated throughout the current study. The goal of this research was to determine the best scenario to provide conditioned supply of air and distribute it inside an office room by using MV and PV systems to create the best status of thermal comfort for a sitting occupant who is typing in front of a computer screen. Thermal comfort mathematical indices like the Predicted Mean Vote (PMV) and the Predicted Percentage of Dissatisfied (PPD) were implemented