Verification of performance Anisotropic Analytical Algorithm (AAA) implemented on Eclipse planning system / Mohamed Sayed Mohamed Fouad ; Supervised Wael M. Elshemey , Nader A. Elsherbini
Material type:
- Eclipse المحمل على نظام تخطيط العلاج الإشعاعى (AAA)تحقيق طريقة الحساب متباين الخواص التحليلية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.04.M.Sc.2015.Mo.V (Browse shelf(Opens below)) | Not for loan | 01010110066427000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.04.M.Sc.2015.Mo.V (Browse shelf(Opens below)) | 66427.CD | Not for loan | 01020110066427000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.12.04.M.Sc.2015.Ha.S Similarity analysis of protein sequences / | Cai01.12.04.M.Sc.2015.Ma.Q Quantitative evaluation of varying physical acquisition parameters in nuclear cardiology / | Cai01.12.04.M.Sc.2015.Ma.Q Quantitative evaluation of varying physical acquisition parameters in nuclear cardiology / | Cai01.12.04.M.Sc.2015.Mo.V Verification of performance Anisotropic Analytical Algorithm (AAA) implemented on Eclipse planning system / | Cai01.12.04.M.Sc.2015.Mo.V Verification of performance Anisotropic Analytical Algorithm (AAA) implemented on Eclipse planning system / | Cai01.12.04.M.Sc.2015.Sa.I Impact of different treatment parameters in esophageal cancer with IMRT / | Cai01.12.04.M.Sc.2015.Sa.I Impact of different treatment parameters in esophageal cancer with IMRT / |
Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics
This study is performed aiming to verify AAA implemented on Eclipse TPS verion 8.6.six tests used in this work which are: 1-open beam (square and rectangular) PDDs and dose profiles at standard SSD. 2-open beam PDDs and dose profile for two field sizes at different SSDs (110 and 120 cm).3- wedged beam PDDs and dose profiles for motorized wedge of angle 60{u00B0}.4- open beam PDDs and dose profiles at oblique incidence, with angles 15{u00B0} and 30{u00B0}.5- blocked beam profiles for 20 x 20cm shaped with MLC and cerrobend blocks.6-Test of internal inhomogeneity for two clinical situations (Nasopharynx and lung case)using TLD and humanoid rando phantom