Analytical studies of the dynamic scan for evaluation of the kidney function in nuclear medicine / Hossam Mahmoud Yassin ; Supervised Maha Anwar Ali , Adel Mohamed Kelany

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Hossam Mahmoud Yassin , 2015Description: 115 P. : charts , facsimiles ; 25cmOther title:
  • دراسة تحليلية للفحوصات الديناميكية لتقدير وظائف الكلى فى الطب النووى [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics Summary: The aim of this study was to evaluate the quality of dynamic radionuclide renal imaging in Egypt. 13 nuclear medicine departments participated. A functional renal phantom was imaged and interpreted as a patient{u2010}like study. Reconstruction and print outs were performed according to the clinical routine of each laboratory. Four nuclear medicine specialists anonymously evaluated the quality of the image sets. The visual scores of the experts were ranked from one to five. In addition, several numerical time{u2010}activity parameters were calculated and compared between the laboratories. The average visual scores of the experts for the image sets were 3.3+/{u2010}0.9 (range 2.4{u2010}4.2). Only six laboratories received a score value of 2 or higher. The average error for the time to reach maximum activity (T (max)) ranged from {u2010}23 to +16% and for the washout time to reach half activity from maximum activity (T (1/2)) ranged from {u2010}39 to +63%. These results suggest that the difference in calculated parameters between laboratories is most probably due to variations in study protocols, analysis programs and human error. The need for external quality assurance and quality improvement in nuclear renal imaging is evident and is recommended for regular use
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.04.Ph.D.2015.Ho.A (Browse shelf(Opens below)) Not for loan 01010110067264000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.04.Ph.D.2015.Ho.A (Browse shelf(Opens below)) 67264.CD Not for loan 01020110067264000

Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics

The aim of this study was to evaluate the quality of dynamic radionuclide renal imaging in Egypt. 13 nuclear medicine departments participated. A functional renal phantom was imaged and interpreted as a patient{u2010}like study. Reconstruction and print outs were performed according to the clinical routine of each laboratory. Four nuclear medicine specialists anonymously evaluated the quality of the image sets. The visual scores of the experts were ranked from one to five. In addition, several numerical time{u2010}activity parameters were calculated and compared between the laboratories. The average visual scores of the experts for the image sets were 3.3+/{u2010}0.9 (range 2.4{u2010}4.2). Only six laboratories received a score value of 2 or higher. The average error for the time to reach maximum activity (T (max)) ranged from {u2010}23 to +16% and for the washout time to reach half activity from maximum activity (T (1/2)) ranged from {u2010}39 to +63%. These results suggest that the difference in calculated parameters between laboratories is most probably due to variations in study protocols, analysis programs and human error. The need for external quality assurance and quality improvement in nuclear renal imaging is evident and is recommended for regular use

Issued also as CD