header
Local cover image
Local cover image
Image from OpenLibrary

Accuracy of implant placement using maxillary and mandibular tissue supported computer aided surgical guides / Ahmed Mustafa Hashim Kotb ; Supervised Mahmoud Mokhtar Elfar , Maha Wagdy Elkerdawy

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ahmed Mustafa Hashim Kotb , 2014Description: 137 P. : photographs ; 25cmOther title:
  • دقة وضع غراسات الاسنان فى الفك العلوى و الفك السفلى باستخدام ادلة جراحية بالكمبيوتر [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: This quasi experimental study was conducted to compare the amount of linear and angular deviation between the virtual position of implants in the preoperative plan and their actual execution into the patient{u2019}s mouth, when using a flapless computer guided implant surgery and tissue-supported computer aided surgical stents. Fifteen completely edentulous patients were recruited from outpatient clinic, Prosthodontic department, Faculty of oral and dental Medicine, Cairo university. After complete denture construction a radiographic template was fabricated from denture duplication. The patients were imaged using CBCT and the DICOM data were imported to computer software for virtual implant planning. The virtual surgical guide was sent for prototyping to construct a computer-guided stent. Surgical execution of implants was done using the fabricated stents. Four implants were placed in each arch. The patients then received a postoperative CBCT scan and the data were sent to the computer software for superimposition. Four parameters were used to measure the amount of deviation named global deviation, lateral deviation, vertical deviation and finally angular deviation
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2014.Ah.A (Browse shelf(Opens below)) Not for loan 01010110067482000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2014.Ah.A (Browse shelf(Opens below)) 67482.CD Not for loan 01020110067482000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

This quasi experimental study was conducted to compare the amount of linear and angular deviation between the virtual position of implants in the preoperative plan and their actual execution into the patient{u2019}s mouth, when using a flapless computer guided implant surgery and tissue-supported computer aided surgical stents. Fifteen completely edentulous patients were recruited from outpatient clinic, Prosthodontic department, Faculty of oral and dental Medicine, Cairo university. After complete denture construction a radiographic template was fabricated from denture duplication. The patients were imaged using CBCT and the DICOM data were imported to computer software for virtual implant planning. The virtual surgical guide was sent for prototyping to construct a computer-guided stent. Surgical execution of implants was done using the fabricated stents. Four implants were placed in each arch. The patients then received a postoperative CBCT scan and the data were sent to the computer software for superimposition. Four parameters were used to measure the amount of deviation named global deviation, lateral deviation, vertical deviation and finally angular deviation

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image