header
Image from OpenLibrary

Accuracy of implant placement using tissue supported single drill versus full sequence computer aided surgical guides / Safaa Kamel Hussein Ahmed ; Supervised Amal Fathy Kaddah , Amr Hosny Elkhadem

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Safaa Kamel Hussein Ahmed , 2015Description: 125 P. : charts , photographs ; 25cmOther title:
  • دقة غرس الاسنان فى الحفر الاحادى مقابل التسلسل الكامل باستخدام ادلة جراحية مدعمة بالانسجة مصممة بالكمبيوتر [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: This study was done to evaluate the linear and angular deviation between the virtual and the actual implant positions for implants inserted using single drill versus full sequence tissue-supported computer aided surgical guide. The sample of this study consisted of fifteen patients randomly selected from outpatient clinic of prosthodontic department, faculty of oral and dental medicine, Cairo university. All patients were completely edentulous, cooperative and with adequate interarch space. Preoperative CBCT was taken while the patients wearing the radiographic stent with three equally distributed radiographic markers. The preoperative CBCT was used for dental implants planning and formation of the surgical stent. During the surgery one side of the dental arch received two implants with full sequence guided approach, while the other side received another two implants with pilot drill guided approach. Through one week after surgery, the second CBCT was taken for all patients while the patients wearing the same preoperative radiographic stent
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2015.Sa.A (Browse shelf(Opens below)) Not for loan 01010110067648000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2015.Sa.A (Browse shelf(Opens below)) 67648.CD Not for loan 01020110067648000

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

This study was done to evaluate the linear and angular deviation between the virtual and the actual implant positions for implants inserted using single drill versus full sequence tissue-supported computer aided surgical guide. The sample of this study consisted of fifteen patients randomly selected from outpatient clinic of prosthodontic department, faculty of oral and dental medicine, Cairo university. All patients were completely edentulous, cooperative and with adequate interarch space. Preoperative CBCT was taken while the patients wearing the radiographic stent with three equally distributed radiographic markers. The preoperative CBCT was used for dental implants planning and formation of the surgical stent. During the surgery one side of the dental arch received two implants with full sequence guided approach, while the other side received another two implants with pilot drill guided approach. Through one week after surgery, the second CBCT was taken for all patients while the patients wearing the same preoperative radiographic stent

Issued also as CD

There are no comments on this title.

to post a comment.