Correlation between kinematic gait parameters and balance in children with diplegic cerebral palsy / Amira Fathy Ibrahim Saeed ; Supervised Faten Hassan Abdelazim , Ali Mustafa Abdelmonem
Material type: TextLanguage: English Publication details: Cairo : Amira Fathy Ibrahim Saeed , 2015Description: 110 P. : charts , facsimiles ; 25cmOther title:- العلاقة بين القياسات الكينيماتيكية للمشى و الاتزان لدى اطفال الشلل الدماغى المزدوج [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.21.06.M.Sc.2015.Am.C (Browse shelf(Opens below)) | Not for loan | 01010110067604000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.21.06.M.Sc.2015.Am.C (Browse shelf(Opens below)) | 67604.CD | Not for loan | 01020110067604000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Growth and Developmental Disorders in Pediatrics
Objective: The purpose of this study was to investigate the correlation between the standing balance and spatiotemporal gait parameters in diplegics and normal children. Subject: Twenty five normally developing children and twenty five children with cerebral palsy spastic diplegia from both sexes with age range 5-9 years old. Methods: Biodex balance system was used for balance assessment, the anteroposterior, mediolateral and overall stability index were measured. Gait was assessed using videography and Corel Draw Graphics Suite (X5) software, the parameters calculated were step length, stride length, velocity, cadence, stance duration and swing duration. Results: There was significant difference between normal children and diplegics in all tested gait parameters and dynamic stability indices. Step length and stride length had direct moderate correlation with velocity and cadence in normal children, while Step length and stride length had direct moderate correlation with only the velocity in diplegics. No correlation was found between the spatiotemporal gait parameters and dynamic stability indices in normal and diplegic children. Conclusion: spatiotemporal gait parameters and standing balance parameters had lower values in children with diplegia than normal children and they were not correlated either in normal or diplegic children
Issued also as CD
There are no comments on this title.