Determination of mbeverine hydrochloride drug using Ion selective electrodes / Veronia Nabil Abdrabou ; Supervised Mohamed Mohamed Omar , Awad Alsyed Ali Signature
Material type:
- تقدير دواء الميبفرين هيدروكلورايد باستخدام الأقطاب الأيونيه الأنتقائيه [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.08.M.Sc.2015.Ve.D (Browse shelf(Opens below)) | Not for loan | 01010110067938000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.08.M.Sc.2015.Ve.D (Browse shelf(Opens below)) | 67938.CD | Not for loan | 01020110067938000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.12.08.M.Sc.2015.Ra.P Potentiometric determination of some surfactants using ion selective electrodes in different water samples / | Cai01.12.08.M.Sc.2015.Sh.E Electrochemical sensors for determination of clomipramine hydrochloride / | Cai01.12.08.M.Sc.2015.Sh.E Electrochemical sensors for determination of clomipramine hydrochloride / | Cai01.12.08.M.Sc.2015.Ve.D Determination of mbeverine hydrochloride drug using Ion selective electrodes / | Cai01.12.08.M.Sc.2015.Ve.D Determination of mbeverine hydrochloride drug using Ion selective electrodes / | Cai01.12.08.M.Sc.2015.Ya.N New methods for analysis and microdetermination of some anti- diabetic and antihypertensive drugs / | Cai01.12.08.M.Sc.2015.Ya.N New methods for analysis and microdetermination of some anti- diabetic and antihypertensive drugs / |
Thesis (M.Sc.) - Cairo University - Faculty of Science- Department of Analytical Chemistry
A simple, rapid and sensitive method for the determination of mebeverine hydrochloride (MBHC) in urine, serum and pharmaceutical preparations using modified carbon paste and screen printed electrodes was developed. The electrochemical sensors showed a linear dynamic range of 3.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² , 1.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² for MCPEs ( sensor I, II) and 1.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² mol L⁻¹ for both MSPEs (sensor II, IV) with detection limit of 3.0{u00D7}10-7 and 1{u00D7}10⁻⁷ mol L-1 for modified carbon paste and screen printed (MCPEs; sensors I ,II MSPEs; III,IV), respectively. The slopes of the calibration graphs are 56.78±0.85, 58.80±0.46, 56.49±0.85 and 57.93±0.46 mV decade-1 for MCPEs and MSPEs with tricresylphosphate (TCP) (sensor I, III), o-nitrophenyloctylether (o-NPOE) (sensor II, IV) as plasticizers, respectively. The response time was relatively quick in the whole concentration range (8, 7, 7 and 6 s) for electrodes I, II, III and IV, respectively. The electrodes can be used at least 65, 73, 140 and 159 days without observing any deviations in a pH range of 2.0 to 8.0 , 1.5 to 8.0, 1.5 to 8.0 and 1.5 to 8.5 for electrodes I , II, III and IV, respectively
Issued also as CD
There are no comments on this title.