header
Local cover image
Local cover image
Image from OpenLibrary

Determination of mbeverine hydrochloride drug using Ion selective electrodes / Veronia Nabil Abdrabou ; Supervised Mohamed Mohamed Omar , Awad Alsyed Ali Signature

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Veronia Nabil Abdrabou , 2015Description: 142 P. : charts ; 25cmOther title:
  • تقدير دواء الميبفرين هيدروكلورايد باستخدام الأقطاب الأيونيه الأنتقائيه [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Science- Department of Analytical Chemistry Summary: A simple, rapid and sensitive method for the determination of mebeverine hydrochloride (MBHC) in urine, serum and pharmaceutical preparations using modified carbon paste and screen printed electrodes was developed. The electrochemical sensors showed a linear dynamic range of 3.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² , 1.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² for MCPEs ( sensor I, II) and 1.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² mol L⁻¹ for both MSPEs (sensor II, IV) with detection limit of 3.0{u00D7}10-7 and 1{u00D7}10⁻⁷ mol L-1 for modified carbon paste and screen printed (MCPEs; sensors I ,II MSPEs; III,IV), respectively. The slopes of the calibration graphs are 56.78±0.85, 58.80±0.46, 56.49±0.85 and 57.93±0.46 mV decade-1 for MCPEs and MSPEs with tricresylphosphate (TCP) (sensor I, III), o-nitrophenyloctylether (o-NPOE) (sensor II, IV) as plasticizers, respectively. The response time was relatively quick in the whole concentration range (8, 7, 7 and 6 s) for electrodes I, II, III and IV, respectively. The electrodes can be used at least 65, 73, 140 and 159 days without observing any deviations in a pH range of 2.0 to 8.0 , 1.5 to 8.0, 1.5 to 8.0 and 1.5 to 8.5 for electrodes I , II, III and IV, respectively
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.08.M.Sc.2015.Ve.D (Browse shelf(Opens below)) Not for loan 01010110067938000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.08.M.Sc.2015.Ve.D (Browse shelf(Opens below)) 67938.CD Not for loan 01020110067938000

Thesis (M.Sc.) - Cairo University - Faculty of Science- Department of Analytical Chemistry

A simple, rapid and sensitive method for the determination of mebeverine hydrochloride (MBHC) in urine, serum and pharmaceutical preparations using modified carbon paste and screen printed electrodes was developed. The electrochemical sensors showed a linear dynamic range of 3.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² , 1.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² for MCPEs ( sensor I, II) and 1.0 {u00D7} 10⁻⁷ {u2013} 1.0 {u00D7} 10⁻² mol L⁻¹ for both MSPEs (sensor II, IV) with detection limit of 3.0{u00D7}10-7 and 1{u00D7}10⁻⁷ mol L-1 for modified carbon paste and screen printed (MCPEs; sensors I ,II MSPEs; III,IV), respectively. The slopes of the calibration graphs are 56.78±0.85, 58.80±0.46, 56.49±0.85 and 57.93±0.46 mV decade-1 for MCPEs and MSPEs with tricresylphosphate (TCP) (sensor I, III), o-nitrophenyloctylether (o-NPOE) (sensor II, IV) as plasticizers, respectively. The response time was relatively quick in the whole concentration range (8, 7, 7 and 6 s) for electrodes I, II, III and IV, respectively. The electrodes can be used at least 65, 73, 140 and 159 days without observing any deviations in a pH range of 2.0 to 8.0 , 1.5 to 8.0, 1.5 to 8.0 and 1.5 to 8.5 for electrodes I , II, III and IV, respectively

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image