Quantitative evaluation of varying physical acquisition parameters in nuclear cardiology / Mahmoud Adel Ahmed Mahmoud ; Supervised Reem Hassan Elgebaly , Monira Mahmoud Rageh
Material type:
- التقييم الكمي للعوامل الفزيائية في التصوير الإشعاعى فى المسح الذري على القلب [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.04.M.Sc.2015.Ma.Q (Browse shelf(Opens below)) | Not for loan | 01010110068011000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.04.M.Sc.2015.Ma.Q (Browse shelf(Opens below)) | 68011.CD | Not for loan | 01020110068011000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.12.04.M.Sc.2015.Al.E Effect of grape seed extract on oxidative stress induced by argon laser beam during eye treatmen / | Cai01.12.04.M.Sc.2015.Ha.S Similarity analysis of protein sequences / | Cai01.12.04.M.Sc.2015.Ha.S Similarity analysis of protein sequences / | Cai01.12.04.M.Sc.2015.Ma.Q Quantitative evaluation of varying physical acquisition parameters in nuclear cardiology / | Cai01.12.04.M.Sc.2015.Ma.Q Quantitative evaluation of varying physical acquisition parameters in nuclear cardiology / | Cai01.12.04.M.Sc.2015.Mo.V Verification of performance Anisotropic Analytical Algorithm (AAA) implemented on Eclipse planning system / | Cai01.12.04.M.Sc.2015.Mo.V Verification of performance Anisotropic Analytical Algorithm (AAA) implemented on Eclipse planning system / |
Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Biophysics
Background: There are various physical factors that limit the quality of the Single Photon Emission Computed Tomography (SPECT) images such as number of frames per projection, number of projections per scan and time per projection in gated myocardial SPECT scan. Objectives: The aim of the present work was to evaluate physical acquisition parameters affecting the cardiac imaging to optimize the patient{u2019}s examination time and image quality that are acquired with the gamma camera and workers radiation protection (through reducing time of radiation exposure) in cardiac SPECT facility using cardiac functional parameters ejection fraction (EF), end diastole volume (EDV), end systole volume (ESV) and total perfusion defect (TPD). RESULTS: There was insignificant difference in the EF, EDV, ESV and TPD between the different groups concerning the number of frames per projection, number of projections per scan and time per projection. CONCLUSION: The reduction of scan time to half or the number of projections per scan to half or increasing the number of frames per scan from 8 to 16 at the same duration has insignificant effect in the cardiac functional parameters used with gated SPECT scan.
Issued also as CD
There are no comments on this title.