Constrained liner in total hip arthroplasty / Yamen Mohamed Wanis ; Supervised Hazem Abdelazeem Ibrahim , Sherif Mamdouh AbdelHafez Amr , Mohamed Mahmoud Mohamed Hegazi
Material type: TextLanguage: English Publication details: Cairo : Yamen Mohamed Wanis , 2015Description: 202 Leaves : facsimiles ; 25cmOther title:- المفصل الصناعى الكامل للفخذ ذو المبطن الكابح للخلع [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.25.Ph.D.2015.Ya.C (Browse shelf(Opens below)) | Not for loan | 01010110068325000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.11.25.Ph.D.2015.Ya.C (Browse shelf(Opens below)) | 68325.CD | Not for loan | 01020110068325000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.11.25.Ph.D.2015.Wa.P Percutaneous fixation of displaced proximal humeral fractures / | Cai01.11.25.Ph.D.2015.Wa.P Percutaneous fixation of displaced proximal humeral fractures / | Cai01.11.25.Ph.D.2015.Ya.C Constrained liner in total hip arthroplasty / | Cai01.11.25.Ph.D.2015.Ya.C Constrained liner in total hip arthroplasty / | Cai01.11.25.Ph.D.2015.Ya.U The use of volar locked plate in fractures of distal radius / | Cai01.11.25.Ph.D.2015.Ya.U The use of volar locked plate in fractures of distal radius / | Cai01.11.25.Ph.D.2016.Ah.C Comparative study between ORIF and limited internal fixation with external fixation for closed distal tibial fractures / |
Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery
The possibility for developing much higher stresses at the shell - bone or liner-shell interface, also it decreased range of motion before impingement compared to the non - constrained component with possible adverse effects on polyethylene wear and osteolysis. Various modes of failure were reported; Type I: in the shell - bone interface, Type II: in the shell - liner interface, Type III: the locking mechanism, Type IV: bipolar - femoral head interface. In primary hip arthroplasty, its incidence has been reported to be between 0.6% and 9.9%. With revision surgery, it can be as high as 20%
Issued also as CD
There are no comments on this title.