Correlation between bone density and primary implants stability in computer guided implant system / Moataz Bealla Mohamed Abdelaziz ; Supervised Samira Ibrahim Ibrahim , Maha Wagdy Elkerdawy
Material type:
- العلاقة بين كثافة العظام و الثبات المبدئى للغرسات فى نظام غرس مساعد بالكمبيوتر [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2015.Mo.C (Browse shelf(Opens below)) | Not for loan | 01010110068574000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2015.Mo.C (Browse shelf(Opens below)) | 68574.CD | Not for loan | 01020110068574000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
The present in vivo study aimed to find the correlation between bone density of implant placement sites and primary stability of implants using a computer guided implant system. Fourteen patients with completely edentulous maxillary and mandibular arches were recruited. Each arch received preplanned four implants based on data obtained from a preoperative cone beam computerized tomography (CBCT). Drilling for the implant was done with the surgical stent secured in its place. After preparation of the osteotomy sites, the implants were threaded with the implant mount using a ratchet. Using the 2measure density in eclipse3 (feature of the Mimics 10.01 software) the bone density in the implant placement sites was recorded, then categorized according to Misch 2008 classification into the four bone types (D1, D2, D3, D4). Clinical evaluation was carried out for implant stability using resonance frequency analysis immediately after implant installation using the Osstell ISQ device. Each Implant{u2019}s stability was measured in the bucco-lingual and the mesio distal direction using the osstell{u2019}s smartpeg tool screwed to the implant. A non significant difference between the primary stability of implants in maxilla and mandible despite the significant difference found between the bone densities of both arches. There is a weak positive relation between the bone densities of implant osteotomy sites (HU) and the primary stability of the implants ISQ
Issued also as CD
There are no comments on this title.