header
Image from OpenLibrary

Restoration of endplate integrity in a type thoracic and lumbar vertebral fractures / Mohamed Mosaad Marouf Naseef ; Supervised Ahmed Ahmed Morrah , Hossam Salah , Ihab Mohamed Emran

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohamed Mosaad Marouf Naseef , 2015Description: 130 P. : charts , facsimiles ; 25cmOther title:
  • إعادة بناء الشريحة النهائية لكسور الفقرات الصدرية والقطنية للنوع ( أ ) باستخدام دعامات: الأسمنت الطبي الحيوي أو كلاهما [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopedic Surgery Summary: This study Three methods were used including balloon in ten cases, instrumented assisted endplate reduction in nine cases, stent in one case, restoration was assessed intra-operative by discography under image intensifier and post-operative using x-rays (cobb{u2019}s angle, vertebral wedge body angle) and CT scan(anterior and mid-vertebral vertebral body height, endplate configuration, lowest point in any sagittal plan cement appearance and leakage.x-rays and CT scan were used to assess patients radiological before and after the operation.restoration of end plate integrity in type A thoracic and lumbar spine fractures is an effective method to prevent disc creeping in the broken endplate so preventing recollapse after correction of body height and cobb{u2019}s angle ,however longer term follow up is needed to reassess the morphological changes in the disc following this method comparing it to traditional posterior fixation only, and further study of the chemical changes in disc following endplate fracture
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.25.Ph.D.2015.Mo.R (Browse shelf(Opens below)) Not for loan 01010110068637000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.25.Ph.D.2015.Mo.R (Browse shelf(Opens below)) 68637.CD Not for loan 01020110068637000

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopedic Surgery

This study Three methods were used including balloon in ten cases, instrumented assisted endplate reduction in nine cases, stent in one case, restoration was assessed intra-operative by discography under image intensifier and post-operative using x-rays (cobb{u2019}s angle, vertebral wedge body angle) and CT scan(anterior and mid-vertebral vertebral body height, endplate configuration, lowest point in any sagittal plan cement appearance and leakage.x-rays and CT scan were used to assess patients radiological before and after the operation.restoration of end plate integrity in type A thoracic and lumbar spine fractures is an effective method to prevent disc creeping in the broken endplate so preventing recollapse after correction of body height and cobb{u2019}s angle ,however longer term follow up is needed to reassess the morphological changes in the disc following this method comparing it to traditional posterior fixation only, and further study of the chemical changes in disc following endplate fracture

Issued also as CD

There are no comments on this title.

to post a comment.