header
Local cover image
Local cover image
Image from OpenLibrary

Effect of lutting resin systems on push out bond strength value of individually formed glass fiber versus glass fiber posts in conservative intra-radicular preparation in endodontically treated anterior teeth : An in vitro study / Mohammed Baraa Adnan Lababidi ; Supervised Omaima Elmahallawi

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohammed Baraa Adnan Lababidi , 2015Description: 110 P. : charts , photographs ; 25cmOther title:
  • تأثير طرق اللصق بالراتنج اللصَّاق على مقدار قوة الإلتصاق لوتد من الألياف الزجاجية مقارنةً مع وتد من الألياف الزجاجية أحادية التشكل فى تحضير محافظ داخل قناة الجذر لأسنانٍ أماميةٍ معالجةً لبياً : فى دراسةٍ مخبرية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: To study the effect of lutting resin systems on push out bond strength value of individually formed glass fiber post versus glass fiber post in conservative intra-radicular preparation in endodontically treated anterior teeth. A total of forty four endodontically treated anterior teeth will be divided into 2 equal groups according to the material of its cementation: First group self adhesive resin cement (control group), second group: Etch and rinse adhesive resin cement. Each group will be further subdivided into 2 subgroups according to the type of fiber posts: subgroup A endodontically treated teeth with a formable glass fiber post 2everStick post2, subgroup B endodontically treated teeth with a glass fiber post. All sample were cutting into 3 slice by micro saw then all samples were subjected to micro - push out bond strength testing under a load parallel to their long axis using computer controlled universal testing machine. Data were collected and statistically analyzed. After push out testing, failure mode of all samples were examined visually and by stereomicroscope. The highest debonding force value was recorded by the fiber post with variolink cement in cervical portion (12.05 ± 1.22 N) followed by fiber post with rely x cement in cervical portion (7.03 ± 0.94 N), everstick post with variolink cement in cervical portion (6.18 ± 1.38 N), while the lowest value was for the everstick post with rely x cement in cervical portion 5.43 ± 1.44 N
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2015.Mo.E (Browse shelf(Opens below)) Not for loan 01010110068585000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2015.Mo.E (Browse shelf(Opens below)) 68585.CD Not for loan 01020110068585000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.M.Sc.2015.Mo.E Efficacy of post length and post material on the pull-out bond strength of individually formable glass fiber post versus custom made metal post on endodontically treated mandibular premolar teeth : An in vitro study / Cai01.09.09.M.Sc.2015.Mo.E The effect of internal and external surface treatments on biaxial flexural strength of enamic hybrid ceramics : An in vitro study / Cai01.09.09.M.Sc.2015.Mo.E The effect of internal and external surface treatments on biaxial flexural strength of enamic hybrid ceramics : An in vitro study / Cai01.09.09.M.Sc.2015.Mo.E Effect of lutting resin systems on push out bond strength value of individually formed glass fiber versus glass fiber posts in conservative intra-radicular preparation in endodontically treated anterior teeth : An in vitro study / Cai01.09.09.M.Sc.2015.Mo.E Effect of lutting resin systems on push out bond strength value of individually formed glass fiber versus glass fiber posts in conservative intra-radicular preparation in endodontically treated anterior teeth : An in vitro study / Cai01.09.09.M.Sc.2015.Mo.E Effect of implant platform switching on strain developed around implants with straight and angled abutments / Cai01.09.09.M.Sc.2015.Mo.E Effect of implant platform switching on strain developed around implants with straight and angled abutments /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

To study the effect of lutting resin systems on push out bond strength value of individually formed glass fiber post versus glass fiber post in conservative intra-radicular preparation in endodontically treated anterior teeth. A total of forty four endodontically treated anterior teeth will be divided into 2 equal groups according to the material of its cementation: First group self adhesive resin cement (control group), second group: Etch and rinse adhesive resin cement. Each group will be further subdivided into 2 subgroups according to the type of fiber posts: subgroup A endodontically treated teeth with a formable glass fiber post 2everStick post2, subgroup B endodontically treated teeth with a glass fiber post. All sample were cutting into 3 slice by micro saw then all samples were subjected to micro - push out bond strength testing under a load parallel to their long axis using computer controlled universal testing machine. Data were collected and statistically analyzed. After push out testing, failure mode of all samples were examined visually and by stereomicroscope. The highest debonding force value was recorded by the fiber post with variolink cement in cervical portion (12.05 ± 1.22 N) followed by fiber post with rely x cement in cervical portion (7.03 ± 0.94 N), everstick post with variolink cement in cervical portion (6.18 ± 1.38 N), while the lowest value was for the everstick post with rely x cement in cervical portion 5.43 ± 1.44 N

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image