Comparison between different ion selective electrodes for determination of moxifloxacin hydrochloride / Marwa Saad Ahmed Abdelrahim ; Supervised Faten A. F. Nour Eldien , Eman Yossri Zaki Frag
Material type: TextLanguage: English Publication details: Cairo : Marwa Saad Ahmed Abdelrahim , 2015Description: 125 P. : charts ; 25cmOther title:- مقارنة بين الأقطاب الأيونية الأنتقالية المختلفه لتقدير دواء الموكسيفلوكساسين هيدروكلوريد [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.08.M.Sc.2015.Ma.C (Browse shelf(Opens below)) | Not for loan | 01010110068952000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.08.M.Sc.2015.Ma.C (Browse shelf(Opens below)) | 68952.CD | Not for loan | 01020110068952000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Analytical Chemistry
In this study, a comparison between modified and in situ screen printed (SPE), carbon paste (CPE) and PVC electrodes was described for determination of moxifloxacin hydrochloride in pure and pharmaceutical formulations. The electrode reveals linear response over wide concentration range of 1.0 {u00D7}10 - 6 - 1.0 {u00D7} 10 - 2 mol L - 1 of MOXHC at 25 oC with a monovalent cationic slope. It was found that the best slopes were 57.2 ± 2.6, 59.2 ± 4.6 and 57.7 ± 2.7 mV decade -1 for IPVC electrodes modified with 7.5 mg NaTPB, 7.5 mg PMA and 7.5 mg PTA, respectively, and 58.6 ± 1.7, 60.0 ± 2.0 and 59.0 ± 3.3 mV decade 1 for ISPE modified with 22 mg NaTPB, 16 mg RN and 30 mg PTA, respectively, but it was 60 ± 2.3 mV decade - 1 for ICPE modified with 10 mg NaTPB and for modified CPE the best ion pair was MOXH - TPB with highest slope value of 58.2 ± 3.4 mV decade 1, While other IPs gave calibration graphs with lower slope values. All electrodes were characterized and optimized with respect to the main experimental parameters affecting the electrode performance, including composition, pH, temperature, response time and showed good selectivity for moxifloxacin hydrochloride (MOXHC) with respect to some inorganic cations, sugars and glycine. The developed electrodes have been used successfully for the determination of moxifloxacin hydrochloride in pharmaceutical preparation using standard addition and calibration methods. The obtained results were in good agreement with those obtained using the official method
Issued also as CD
There are no comments on this title.