Reliabilty of using kinovea program in upper limb range of motion measurment / Reham Mohamed Abd El-Rahim ; Supervised Ragia Mohamed Kamel , Mohamed Farouk Ali , Eman Ahmed Abdelmoez
Material type:
- مصداقية استخدام برنامج كينوفا فى قياس المدى الحركى للطرف العلوى [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.21.09.Ph.D.2016.Re.R (Browse shelf(Opens below)) | Not for loan | 01010110069451000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.21.09.Ph.D.2016.Re.R (Browse shelf(Opens below)) | 69451.CD | Not for loan | 01020110069451000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.21.09.Ph.D.2016.Mo.E Effect of cross education in unilateral immobilization using elbow support on contralateral muscle torque in tennis elbow / | Cai01.21.09.Ph.D.2016.Ra.E Effects of age and gender on facial movements : Utilizing moire topography / | Cai01.21.09.Ph.D.2016.Ra.E Effects of age and gender on facial movements : Utilizing moire topography / | Cai01.21.09.Ph.D.2016.Re.R Reliabilty of using kinovea program in upper limb range of motion measurment / | Cai01.21.09.Ph.D.2016.Re.R Reliabilty of using kinovea program in upper limb range of motion measurment / | Cai01.21.09.Ph.D.2016.Sh.V Validity and reliability of kinovea computer program in cervical range of motion measurements / | Cai01.21.09.Ph.D.2016.Sh.V Validity and reliability of kinovea computer program in cervical range of motion measurements / |
Thesis (Ph.D.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science
This study was conducted to investigate the intra-rater and inter-rater reliabilities of the Kinovea software for the measurement of upper limb joints range of motion in normal individuals. Subjects, Materials and Methods: The shoulder, elbow and wrist joints range of motion was evaluated in a sample of one hundred normal participants aged between (20-35) years, using Kinovea software by three trained raters. Measurements were taken in a blinded random manner to test the Inter-rater reliability. Intra-rater reliability was examined by a single rater. Results: ± SD of age was (27.6±4.2) years, height was (168.9±7) cm and weight was (69.9±8.2) kg. The inter-rater reliability ranged from Inter-Correlation Coefficient of (0.87 to 0.98), while the inra-rater reliability ranged from Inter-Correlation Coefficient of (0.92 to 0.99). The standard error of measurement performed with Kinovea ranged between (0.88{u00B0} and 1.3{u00B0}) for the inter-rater reliability, and (0.6{u00B0} and 0.86{u00B0}) for the intra-rater reliability. The minimal detectable change was between (2.5{u00B0} and 3.6{u00B0}) for the inter-rater reliability and between (1.7{u00B0} and 2.4{u00B0}) for the intra-rater reliability. Conclusion: The current study presented high reliability and low minimal detectable change for upper limb joints range of motion measures obtained with Kinovea software when used in normal individuals. The inter-rater reliability was higher than the intra-rater reliability
Issued also as CD
There are no comments on this title.