header
Image from OpenLibrary

Effect of elevated temperature on punching strength of flat slabs in compression side / Peter Kamil Fakhry Auob ; Supervised Mostafa Fouad Elkafrawy , Said Aly Mohamed Taher

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Peter Kamil Fakhry Auob , 2016Description: 89 P. : charts , facsimiles ; 30cmOther title:
  • تأثير ارتفاع درجات الحرارة على مقاومة القص الثاقب فى البلاطات المسطحة من جانب الضغط [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering Summary: An experimental investigation was carried out on normal strength concrete flat slab to study punching strength under the effect of elevated temperature. The experimental investigation conducted on 10 slab-column connection specimens with 8 specimens have been exposed to high temperature for different durations with different concrete covers and different cooling types are represented in the present investigation. The slabs were subjected to elevated temperature 600{u00BA} c from the electrical furnace, these durations are 2.0 and 3.0 hours
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2016.Pe.E (Browse shelf(Opens below)) Not for loan 01010110069406000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2016.Pe.E (Browse shelf(Opens below)) 69406.CD Not for loan 01020110069406000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering

An experimental investigation was carried out on normal strength concrete flat slab to study punching strength under the effect of elevated temperature. The experimental investigation conducted on 10 slab-column connection specimens with 8 specimens have been exposed to high temperature for different durations with different concrete covers and different cooling types are represented in the present investigation. The slabs were subjected to elevated temperature 600{u00BA} c from the electrical furnace, these durations are 2.0 and 3.0 hours

Issued also as CD

There are no comments on this title.

to post a comment.