header
Image from OpenLibrary

Evaluation of early nasal continuous positive airway pressure management in preterm babies / Walaa Mahmoud Taher Hamed ALazamy ; Supervised Mohammed Elsayed Hashem , Hanna Mohamed Abuolghar , Sherif ELanwary Abdelmoneim

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Walaa Mahmoud Taher Hamed ALazamy , 2016Description: 142 P. : charts , facsimiles ; 25cmOther title:
  • التقييم المبكر لجهاز السيباب كعلاج للاطفال المبتسرين [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics Summary: To evaluate the predictors associated with early failure of nasal CPAP treatment in preterm babies less than 34 weeks gestation. Patient and Methods: We observed 50 neonates initiated immediately or within 6 hours of birth on nasal CPAP for respiratory distress syndrome. CPAP was administered through neopuff starting from delivery room then shifted to NICU on variable flow CPAP using short binasal prongs and nasal mask CPAP.Results: Primary outcomes of the study were success group that included 32 neonates (64%).While CPAP failure group, who required mechanical ventilation after CPAP failure, included 18 neonates (36%). Our result include predictors for early nasal CPAP failure that showed that the gestational age ,body weight, Sever acidosis , initial Fio2 , initial PEEP and PDA in the echo were the best sensitive independent parameters that can predict CPAP failure. Conclusion: Causes of CPAP failure were multifactorial and combining gestational age, birth weight, the initial fraction of inspired oxygen, initial PEEP, Severe acidosis, and PDA allows for a better and more individualized prediction of early nasal continuous positive airway pressure failure in preterm infants less than 34weeks gestation.Further study to include all types of respiratory distress other than RDS that may affect neonates not only preterm and the use of CPAP in their management is recommended
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.28.M.Sc.2016.Wa.E (Browse shelf(Opens below)) Not for loan 01010110069495000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.28.M.Sc.2016.Wa.E (Browse shelf(Opens below)) 69495.CD Not for loan 01020110069495000

Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics

To evaluate the predictors associated with early failure of nasal CPAP treatment in preterm babies less than 34 weeks gestation. Patient and Methods: We observed 50 neonates initiated immediately or within 6 hours of birth on nasal CPAP for respiratory distress syndrome. CPAP was administered through neopuff starting from delivery room then shifted to NICU on variable flow CPAP using short binasal prongs and nasal mask CPAP.Results: Primary outcomes of the study were success group that included 32 neonates (64%).While CPAP failure group, who required mechanical ventilation after CPAP failure, included 18 neonates (36%). Our result include predictors for early nasal CPAP failure that showed that the gestational age ,body weight, Sever acidosis , initial Fio2 , initial PEEP and PDA in the echo were the best sensitive independent parameters that can predict CPAP failure. Conclusion: Causes of CPAP failure were multifactorial and combining gestational age, birth weight, the initial fraction of inspired oxygen, initial PEEP, Severe acidosis, and PDA allows for a better and more individualized prediction of early nasal continuous positive airway pressure failure in preterm infants less than 34weeks gestation.Further study to include all types of respiratory distress other than RDS that may affect neonates not only preterm and the use of CPAP in their management is recommended

Issued also as CD

There are no comments on this title.

to post a comment.