Design, development and calibration of torque standard machine / Khaled Abdelaziz Mohamed Abdelrhem ; Supervised Mahmoud G. Elsherbiny , Ali E. Abuelezz

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Khaled Abdelaziz Mohamed Abdelrhem , 2016Description: 129 P. : charts , facsimiles ; 30cmOther title:
  • تصميم وتطوير ومعايرة ماكينة مرجعية لمعايرة العزوم [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Design and Production Summary: A NIS 1 kN·m secondary standard torque calibration machine designed earlier [1] is further developed to be a primary standard torque calibration machine. Design and construction of a lever-mass system with ends to be coaxial with the transducer axis are implemented. FEM analysis is used to check the mechanical stresses occurring in the critical components affecting the deflection in the designed lever arm. Procedures for accurate measurements torque arm are described. Expected relative expanded uncertainty is worked out to be 2·10-4. A study on the effect of relative humidity and temperature on the DMP40 measuring amplifier and the BN100A bridge calibration unit as one of the main sources of torque machine uncertainty is reported. Furthermore, the effect of relative humidity on the zero signal of torque transducers is investigated. Finally a study of the influence of temperature and relative humidity on the sensitivity and the characteristics of torque transducers such as residual zero torque, reversibility and creep, is presented. Equations are presented to predict the effect of temperature/relative humidity changes on the sensitivity of torque transducers
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.13.Ph.D.2016.Kh.D (Browse shelf(Opens below)) Not for loan 01010110069634000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.13.Ph.D.2016.Kh.D (Browse shelf(Opens below)) 69634.CD Not for loan 01020110069634000

Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Design and Production

A NIS 1 kN·m secondary standard torque calibration machine designed earlier [1] is further developed to be a primary standard torque calibration machine. Design and construction of a lever-mass system with ends to be coaxial with the transducer axis are implemented. FEM analysis is used to check the mechanical stresses occurring in the critical components affecting the deflection in the designed lever arm. Procedures for accurate measurements torque arm are described. Expected relative expanded uncertainty is worked out to be 2·10-4. A study on the effect of relative humidity and temperature on the DMP40 measuring amplifier and the BN100A bridge calibration unit as one of the main sources of torque machine uncertainty is reported. Furthermore, the effect of relative humidity on the zero signal of torque transducers is investigated. Finally a study of the influence of temperature and relative humidity on the sensitivity and the characteristics of torque transducers such as residual zero torque, reversibility and creep, is presented. Equations are presented to predict the effect of temperature/relative humidity changes on the sensitivity of torque transducers

Issued also as CD

There are no comments on this title.

to post a comment.