header
Image from OpenLibrary

Evaluation of hardness and fracture resistance of surface treated Zirconia on enamel wear : An In-vitro study / Mostafa ElSayed AbouShahba ; Supervised Hesham Katamish , Mona Elagroudy

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mostafa ElSayed AbouShahba , 2015Description: 137 P. : charts , facsimiles ; 25cmOther title:
  • تقيم تأثير الصلابه و مقاومة الكسر للزركونيا المعالجه السطح على تأكل المينا : دراسه معملية [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: Two types of InCoris zirconia blocks were used in this study (ZI and TZI), Stainless Steel dies with dimensions of maxillary molars were used, duplicated using addition silicon impression material to form twenty four epoxy dies, then dies were scanned by the OmniCam. Software designing of crowns and copings was performed, then milling of the presintered blocks was done followed by separation of crowns and copings from the blocks and finishing. Sintering of zirconia blocks was done afterwards, regarding the copings feldspathic porcelain was used with the layering technique to veneer the copings to produce full anatomic crowns. All samples were then polished using special polishing kit for zirconia and glass ceramics and thermal ageing was done for two group using an autoclave at 135{u00B0}C and 2 atmospheric pressure for 5 hours. The twenty four specimens were weighed before wear testing using a sensitive electronic balance then inserted in a custom made wear machine that simulated the wear mechanism that occurs in the oral cavity with natural mandibular molars as antagonists under a weight of 5kg (49 N) and the rotation was of 240 cycles/min, the total time of wear was 8 hours, so the total cycles performed were 120,000 cycles. The twenty four specimens were weighed again after wear testing for the weight loss measurements determination. One specimen from each tested group was randomly selected and viewed under Scanning Electron Microscope in order to determine the wear pattern. Specimens over their corresponding previously poured epoxy dies were loaded with 5 kN until failure occurred. Vicker{u2019}s hardness testing was the performed for all the specimens in order to detect Vicker{u2019}s hardness number
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2015.Mo.E (Browse shelf(Opens below)) Not for loan 01010110069790000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2015.Mo.E (Browse shelf(Opens below)) 69790.CD Not for loan 01020110069790000

Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

Two types of InCoris zirconia blocks were used in this study (ZI and TZI), Stainless Steel dies with dimensions of maxillary molars were used, duplicated using addition silicon impression material to form twenty four epoxy dies, then dies were scanned by the OmniCam. Software designing of crowns and copings was performed, then milling of the presintered blocks was done followed by separation of crowns and copings from the blocks and finishing. Sintering of zirconia blocks was done afterwards, regarding the copings feldspathic porcelain was used with the layering technique to veneer the copings to produce full anatomic crowns. All samples were then polished using special polishing kit for zirconia and glass ceramics and thermal ageing was done for two group using an autoclave at 135{u00B0}C and 2 atmospheric pressure for 5 hours. The twenty four specimens were weighed before wear testing using a sensitive electronic balance then inserted in a custom made wear machine that simulated the wear mechanism that occurs in the oral cavity with natural mandibular molars as antagonists under a weight of 5kg (49 N) and the rotation was of 240 cycles/min, the total time of wear was 8 hours, so the total cycles performed were 120,000 cycles. The twenty four specimens were weighed again after wear testing for the weight loss measurements determination. One specimen from each tested group was randomly selected and viewed under Scanning Electron Microscope in order to determine the wear pattern. Specimens over their corresponding previously poured epoxy dies were loaded with 5 kN until failure occurred. Vicker{u2019}s hardness testing was the performed for all the specimens in order to detect Vicker{u2019}s hardness number

Issued also as CD

There are no comments on this title.

to post a comment.