Evaluation of force reduction factor for steel moment resisting frames, and concentric braced frames in the Egyptian code / Khaled Ahmed Attia Mohamed Abbis ; Supervised Sherif Ahmed Mourad , Fouad Fayez Aly

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Khaled Ahmed Attia Mohamed Abbis , 2016Description: 150 P. : charts , plans ; 30cmOther title:
  • تقدير معامل التخفيض الزلزالي للإطارات المعدنية المقاومة للعزوم و الإطارات المعدنية الملجمة في الكود المصري [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering Summary: Force reduction factor is one of the most important seismic design parameters to consider nonlinear behavior of structures during strong earthquakes. Based on this, all seismic codes allow reducing earthquake loads to match the actual behavior of structures under earthquakes. In the Egyptian Code for Calculation of Loads, base shear is determined using the elastic strength demand divided by strength reduction factor. This factor is used to consider the ability and the efficiency of structure to dissipate seismic energy through inelastic deformation presented in plastic hinges. It consists of three main components representing ductility, over-strength and redundancy of the building. These factors depend mainly on properties of both the structural system of the building and affecting ground motion. This research focuses on the assessment of the ductility reduction factor which is considered the major component of the reduction factor. Steel moment resisting frames (MRFs) and steel concentric braced frames (CBFs) regular and irregular systems are studied for different heights, different ground accelerations, different response spectrum type and different soil type. It is concluded the significant effect of the previously mentioned parameters on the seismic reduction factor that need to be considered in the Egyptian Code of Loads
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2016.Kh.E (Browse shelf(Opens below)) Not for loan 01010110070073000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.05.M.Sc.2016.Kh.E (Browse shelf(Opens below)) 70073.CD Not for loan 01020110070073000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering

Force reduction factor is one of the most important seismic design parameters to consider nonlinear behavior of structures during strong earthquakes. Based on this, all seismic codes allow reducing earthquake loads to match the actual behavior of structures under earthquakes. In the Egyptian Code for Calculation of Loads, base shear is determined using the elastic strength demand divided by strength reduction factor. This factor is used to consider the ability and the efficiency of structure to dissipate seismic energy through inelastic deformation presented in plastic hinges. It consists of three main components representing ductility, over-strength and redundancy of the building. These factors depend mainly on properties of both the structural system of the building and affecting ground motion. This research focuses on the assessment of the ductility reduction factor which is considered the major component of the reduction factor. Steel moment resisting frames (MRFs) and steel concentric braced frames (CBFs) regular and irregular systems are studied for different heights, different ground accelerations, different response spectrum type and different soil type. It is concluded the significant effect of the previously mentioned parameters on the seismic reduction factor that need to be considered in the Egyptian Code of Loads