Micro-shear bond strength of resin composite to two dentin depths following desensitization / Hassan Nader Hassan Negm ; Supervised Mona Ismail Riad , Aliaa Mohamed Elwakeel
Material type:
- قوة الربط القص الدقي للراتنج المركب إلى عمقين من العاج بعد تثبيط الحساسية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.02.M.Sc.2016.Ha.M (Browse shelf(Opens below)) | Not for loan | 01010110071846000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.02.M.Sc.2016.Ha.M (Browse shelf(Opens below)) | 71846.CD | Not for loan | 01020110071846000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Endodontics
This study was conducted to compare the bond strength of etch-and-rinse 2Adper Single Bond 23 (3M ESPE) and self-etch adhesive system 2Single Bond Universal3 (3M ESPE) before and after application of two desensitizing agent: glutaraldehyde based 2Telio3 (Ivoclar Vivadent) and hydroxyapatite nanoparticles bonded to superficial and deep dentin.Thirty freshly extracted human molars were utilized in this study for micro-shear bond strength testing. Each molar was sectioned in order to obtain dentin specimens at two depths: superficial dentin at 0.5mm below the dentino-enamel junction (DEJ) and deep dentin at 1.5mm below the DEJ resulting in 60 specimens (30 each depth). Each dentin specimen was divided into two halves according to the adhesive system used, then divided into three subgroups according to the surface treatment into control (no treatment), hydroxyapatite nanoparticles and glutaraldehyde based desensitizing agent.Micro-shear bond strength test was carried out by using translucent microtubules with an internal diameter of 1 mm and 1 mm height. The microtubules were placed on the prepared dentin specimen to be filled with the composite resin material 2Filtek Z350XT3 (3M ESPE) after application of desensitizing agents and the adhesive systems. All specimens were stored in distilled water for 24 hours. Micro-shear bond strength was assessed using a universal testing machine in a pull motion. Environmental Scanning electron microscope
Issued also as CD
There are no comments on this title.