header
Image from OpenLibrary

The use of ultrasound in assessment of the lower uterine segment thickness in patients with previous cesarean section / Huda Mohammed Shafeek ; Supervised Maged Ahmed Abdelraouf , Hisham Mohamed Gouda , Mohammed Hamam Abdmanaf

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Huda Mohammed Shafeek , 2016Description: 87 P. : charts , facsimiles ; 25cmOther title:
  • استخدام الموجات فوق الصوتية في قياس سمك الجزء السفلي من الرحم في الحالات التي اجري لها ولادة قيصرية سابقا [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Gynecology and Obstetrics Summary: Objective To assess the value of ultrasound use (abdominal and transvaginal) in measurement of the lower uterine segment thickness in women with previous CS, and to determine a cut-off value that can be clinically used to allow a safe vaginal birth after cesarean (VBAC).Methods The lower uterine segment thickness was measured by both transabdominal and transvaginal ultrasound in 200 cases, gravidas (37 week {u2013} 40 week) ,100 cases with previous CS (study group) undergoing repeated CS , and the other 100 cases without any scar in the uterus(control group), then the grade of the scar was assessed intraoperatively.Results We concluded that a best cut-off value was at 3.5mm (using TVS) and this yielded a sensitivity of 63.6% and a specificity of 79.4% at this cut-off value, the positive predictive value was 85.7% while the negative predictive value was 52.9% and the accuracy was 69%. By TAS the best cut- off value was 2.5mm and this yielded a sensitivity of 77.3% and a specificity of 73.5%. At this cut-off value, the positive predictive value was 85% while the negative predictive was 62.5% and the accuracy was 76%.Conclusion Ultrasonographic evaluation permits good assessment of the risk of scar complications intra partum. The lower uterine segment thickness is related to the grade of the scar. The best timing to perform the scan is at late third trimester. A cut-off value of 3.5 mm by TVS, and 2.5 mm by TAS can be safely used with high degree of sensitivity and specificity
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.15.M.Sc.2016.Hu.U (Browse shelf(Opens below)) Not for loan 01010110071894000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.15.M.Sc.2016.Hu.U (Browse shelf(Opens below)) 71894.CD Not for loan 01020110071894000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.11.15.M.Sc.2016.He.R Role of 3D-U/S and doppler indices in evaluating endometrial lining in postmenopausal women and its correlation with body mass index and histopathological examination / Cai01.11.15.M.Sc.2016.Ho.C Comparative study of total dose infusion of iron and intramuscular iron administration in treatment of severe iron deficiency anemia during pregnancy / Cai01.11.15.M.Sc.2016.Ho.C Comparative study of total dose infusion of iron and intramuscular iron administration in treatment of severe iron deficiency anemia during pregnancy / Cai01.11.15.M.Sc.2016.Hu.U The use of ultrasound in assessment of the lower uterine segment thickness in patients with previous cesarean section / Cai01.11.15.M.Sc.2016.Hu.U The use of ultrasound in assessment of the lower uterine segment thickness in patients with previous cesarean section / Cai01.11.15.M.Sc.2016.Ka.U The use of international ovarian tumour analysis (IOTA) simple rules and the assessment of different neoplasia in the adnexa (ADNEX) model In differentiating between malignant and benign adnexal masses / Cai01.11.15.M.Sc.2016.Ka.U The use of international ovarian tumour analysis (IOTA) simple rules and the assessment of different neoplasia in the adnexa (ADNEX) model In differentiating between malignant and benign adnexal masses /

Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Gynecology and Obstetrics

Objective To assess the value of ultrasound use (abdominal and transvaginal) in measurement of the lower uterine segment thickness in women with previous CS, and to determine a cut-off value that can be clinically used to allow a safe vaginal birth after cesarean (VBAC).Methods The lower uterine segment thickness was measured by both transabdominal and transvaginal ultrasound in 200 cases, gravidas (37 week {u2013} 40 week) ,100 cases with previous CS (study group) undergoing repeated CS , and the other 100 cases without any scar in the uterus(control group), then the grade of the scar was assessed intraoperatively.Results We concluded that a best cut-off value was at 3.5mm (using TVS) and this yielded a sensitivity of 63.6% and a specificity of 79.4% at this cut-off value, the positive predictive value was 85.7% while the negative predictive value was 52.9% and the accuracy was 69%. By TAS the best cut- off value was 2.5mm and this yielded a sensitivity of 77.3% and a specificity of 73.5%. At this cut-off value, the positive predictive value was 85% while the negative predictive was 62.5% and the accuracy was 76%.Conclusion Ultrasonographic evaluation permits good assessment of the risk of scar complications intra partum. The lower uterine segment thickness is related to the grade of the scar. The best timing to perform the scan is at late third trimester. A cut-off value of 3.5 mm by TVS, and 2.5 mm by TAS can be safely used with high degree of sensitivity and specificity

Issued also as CD

There are no comments on this title.

to post a comment.