The effect of using thermo-plastic acrylic denture base versus conventional acrylic denture base on the supporting structures in implant retained mandibular over-denture : A randomized clinical trial / Miran Hassan Elsayed Sultan ; Supervised Alaa AboulEla , Mahmoud Salloum
Material type: TextLanguage: English Publication details: Cairo : Miran Hassan Elsayed Sultan , 2016Description: 91 P. : facsimiles ; 25cmOther title:- دراسة تأثير مادة الأكريل المرنة مقارنة بالأكريل العادى: على الأنسجة المدعمة: فى قواعد الأطقم السفلية المثبتة بغرسات سنية : تجربة سريرية للتحكم الجزافى [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.Ph.D.2016.Mi.E (Browse shelf(Opens below)) | Not for loan | 01010110071925000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.Ph.D.2016.Mi.E (Browse shelf(Opens below)) | 71925.CD | Not for loan | 01020110071925000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
This study was conducted to evaluate the effect of using the thermo-plastic acrylic denture base versus using the conventional acrylic denture base on the supporting structures in implant retained mandibular overdenture. Twelve completely edentulous male patients were included in the study.They were divided in to two groups, group A: (experimental group) and group B: (control group) Group A: Six patients were included, each patient had a mandibular implant retained over-dentures using thermo-plastic acrylic denture base (versacryl). Group B: Six Patients were included, each patient had aMandibular implant retained over-dentures using conventional acrylic denture base. Patient{u2019}s satisfaction and radiographic evaluations were carried out for every patient at 3, 6 and 9 months of the functional loading. Assessment of the patient{u2019}s satisfaction was performed using a questionnaire with score measurement. The questionnaire showed that there was a significant increase in patient{u2019}s satisfaction in experimental group, than the control group. (p<0.05). Assessment of the periimplant bone loss was performed by direct digital radiography (DDR) using digora computerized system. The radiographic assessment showed at 3,6and 9months it was found that the peri-implant bone loss in experimental group was significantly lower than the conventional group
Issued also as CD
There are no comments on this title.