Flexural cyclic fatigue of twisted rotary nickel-titanium files after simulated clinical use / Abdelrahman Saeed Abdullah Morsi ; Supervised Hebatallah Mohamed Maged Elfar , Wafaa Ahmed Omar Segari
Material type: TextLanguage: English Publication details: Cairo : Abdelrahman Saeed Abdullah Morsi , 2016Description: 115 P. : charts , facsimiles , photographs ; 25cmOther title:- الإجهاد الدوري العاطفي لملفات النيكل تايتيينيوم الدوارة الملتوية و تأثير الاستخدام المشابه للاستخدام السريري عليه [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.02.M.Sc.2016.Ab.F (Browse shelf(Opens below)) | Not for loan | 01010110072515000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.02.M.Sc.2016.Ab.F (Browse shelf(Opens below)) | 72515.CD | Not for loan | 01020110072515000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Endodontics
The purpose of this study was to evaluate the effect of simulated clinical use on the cyclic fatigue of TF and to examine fracture characteristics of fractured segments using SEM.A total of 54 TF (18 sets) were used to prepare moderately curved root canals. Each set had three file sizes (25/ 0.08 - 25/ 0.06 - 30/ 0.06). The files were divided into control group or unused group and experimental group. The experimental group was divided into three subgroups according to the number of canals that was prepared, 3, 6 and 9 canals. After clinical use, the TFs were rotated in stainless steel canals until fracture. The artificial canals for cyclic fatigue testing were made with a tapered shape corresponding to the dimensions of the tested TF with an angle of curvature of 60 degrees and radius of curvature of 5 mm. the files then tested in cyclic fatigue testing device to determine their cyclic fatigue.The results showed statistically significant difference (P<0.05) in cycles to failure between new and used (control group and experimental group) as revealed by two way ANOVA test. Pair-wise Newman-Keuls post-hoc tests revealed that the difference in NCF between three canals subgroup and six canals subgroup was statistically non-significant (p>0.05). The difference between control group and each subgroup and between other subgroups were statistically significant (p<0.05). Regardless the number of canals prepared, two way ANOVA test showed statistically significant difference in NCF mean values between TF sizes (P<0.05). Pair-wise Newman-Keuls post-hoc tests revealed that the difference between 25/0.08 TF and 30/0.06 TF was statistically non-significant (p>0.05) while the difference between 25/0.06 TF and the other TF sizes (25/0.08 TF and 30/0.06 TF) was statistically significant (p < 0.05). Scanning electron microscopy evaluation of test samples revealed that the fracture surfaces showed the characteristic features of ductile fracture
Issued also as CD
There are no comments on this title.