header
Local cover image
Local cover image
Image from OpenLibrary

Comparative study between phaco one - chop nucleotomy technique and divide and conquer technique in phacoemulsification / Ashraf Ahmed Nosseir ; supervised Effat Abd El Nabi , Ahmed Mostafa , Ghada Gawdat

By: Contributor(s): Language: Eng Publication details: Cairo : Ashraf Ahmed Nosseir , 2006Description: 105P : ill ; 25cmOther title:
  • دراسة مقارنة بين اسلوب القطع الواحد للنواة واسلوب التقسيم والاخضاع فى عملية تفتيت المياه البيضاء بالموجات فوق الصوتية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (PH.D.) - Cairo University - Faculty Of Medicine - Department Of Ophthalmology Summary: In this study we have compared the one chop nucleotomy technique (one of the chopping techniques) with the divide and conquer technique (one of the nuclear cracking techniques) The results were recorded including their effects on the corneal endothelium and the corneal thicknessEquivalent phaco time (EPT) , total energy used , intra - operative and postoperative complications were also recordedEPT and total energy were less in the phaco one - chop technique with statistically significant differences
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.24.Ph.D.2006.As.C. (Browse shelf(Opens below)) Not for loan 01010110045345000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.24.Ph.D.2006.As.C. (Browse shelf(Opens below)) Not for loan 01020110045345000

Thesis (PH.D.) - Cairo University - Faculty Of Medicine - Department Of Ophthalmology

In this study we have compared the one chop nucleotomy technique (one of the chopping techniques) with the divide and conquer technique (one of the nuclear cracking techniques) The results were recorded including their effects on the corneal endothelium and the corneal thicknessEquivalent phaco time (EPT) , total energy used , intra - operative and postoperative complications were also recordedEPT and total energy were less in the phaco one - chop technique with statistically significant differences

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image