In vitro comparative study of dimensional changes of polyether & additional silicone impression materials for bounded partially edentulous / Shereen Salah Eldin Morsy Seddik ; Supervised Nadia Abbas , Nouran AbdelNabi , Tamer Mahmoud Ahmed
Material type: TextLanguage: English Publication details: Cairo : Shereen Salah Eldin Morsy Seddik , 2016Description: 63 P. : charts , facsimiles ; 25cmOther title:- دراسة معملية لمقارنة تغير الابعاد لمادتي القياس بولي اثير والسيليكون بالاضافة لحالات الحافة الدردرية الجزئية المحددة [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2016.Sh.I (Browse shelf(Opens below)) | Not for loan | 01010110074008000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2016.Sh.I (Browse shelf(Opens below)) | 74008.CD | Not for loan | 01020110074008000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
Dimensional accuracy is one of the most important factors that govern the accuracy of any impression material, and consequently the accuracy of any impression. The aim of this in-vitro study was to compare the dimensional changes of two impression materials; polyether and addition silicone using both a digital caliper and computerized digital software. A maxillary partially edentulous Kennedy class III with modification 1 acrylic model was used in this experiment. The model had acrylic teeth with missing second premolar and first molar bilaterally. The teeth and the cast was prepared to ensure proper seating of the custom tray fabricated. A dot shaped elevation was prepared on the middle of the occlusal surface of the first premolar and third molar, and on the base of the cast five box shaped reference marks with parallel walls were drilled on the buccal side of the cast, anteriorly and posteriorly, and on both sides. After the cast was prepared, a 2 base plate wax spacer was adapted over the cast, and custom made clear self-cure acrylic resin was fabricated to be adapted to the full extensions of the cast, including the box-shaped reference marks. Two impression materials ; polyether and additional silicone was used in this study. A total of 20 impressions were made, 10 impressions with polyether in the first group and 10 impressions with additional silicone in the second group, in both groups the same tray was used
Issued also as CD
There are no comments on this title.