header
Image from OpenLibrary

Marginal accuracy and fracture resistance of milled zirconia restorations using two veneering techniques = الدقة الحافية و مقاومة الكسر لترميمات الزركونيا المحفورة اليا باستخدام طريقتين للتكسية / Sara Alaa Eldin Mohammed Kamal ; Supervised Shereen Adel Ameen , Zeinab Nabil Emam

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Sara Alaa Eldin Mohammed Kamal , 2016Description: 119 P. : charts , facsimiles , photographs ; 25cmOther title:
  • الدقة الحافية و مقاومة الكسر لترميمات الزركونيا المحفورة اليا باستخدام طريقتين للتكسية [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: The aim of the present study is to evaluate the marginal accuracy and fracture resistance of zirconia restoration using two finish line types, two veneering techniques and two margin designs. A total of 40 zirconia crowns were used. The samples were divided into 2 groups and two sub groups and two sub division groups; according to two finish line types, two veneering technique and two margin designs. Two specially constructed metal dies were machine milled representing upper first premolar preparation to receive all-ceramic restoration. The first die had deep chamfer finish line, while the second die had shoulder finish line. A total number of forty zirconia copings were constructed. They were divided in two main groups, 20 samples each. Group (A): Samples with deep chamfer finish line. Group (B): Samples with shoulder finish line. Samples of each group were subdivided into two equal subgroups (10 samples) according to the technique of veneer application. Sub group }: Veneering material was applied using layering technique. Sub group {u2161}: Veneering material was applied using press on technique. Each subgroup was further sub divided into two equal sub divisions (5 samples each) according to the type of the material at the restoration margin. Sub division }: Coping margin was made up of zirconia material (zirconia margin). Sub division {u2161}: Coping margin was cutback by 1 mm and IPS e.max was added cut back margin (e.max margin). Zirconia copings were constructed on prefabricated metal dies using the Zirkonzahn CAD/CAM system; Also CAD wax was constructed for press on technique with the same system. Either layering or pressing veneering techniques were performed according to manufactures instructions. Marginal accuracy and fracture resistance were used as testing methods. Scanning electron microscope was used to detect the mode of failure
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2016.Sa.M (Browse shelf(Opens below)) Not for loan 01010110074602000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2016.Sa.M (Browse shelf(Opens below)) 74602.CD Not for loan 01020110074602000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.M.Sc.2016.Re.E Evaluation of vertical marginal gap distance and internal adaptation of (Enamic) hybrid ceramic implant-supported superstructure compared to metal- ceramics : An in vitro study / Cai01.09.09.M.Sc.2016.Sa.I Influence of cooling rate on flexural strength of zirconia veneered with two different veneering ceramics / Cai01.09.09.M.Sc.2016.Sa.I Influence of cooling rate on flexural strength of zirconia veneered with two different veneering ceramics / Cai01.09.09.M.Sc.2016.Sa.M Marginal accuracy and fracture resistance of milled zirconia restorations using two veneering techniques = الدقة الحافية و مقاومة الكسر لترميمات الزركونيا المحفورة اليا باستخدام طريقتين للتكسية / Cai01.09.09.M.Sc.2016.Sa.M Marginal accuracy and fracture resistance of milled zirconia restorations using two veneering techniques = الدقة الحافية و مقاومة الكسر لترميمات الزركونيا المحفورة اليا باستخدام طريقتين للتكسية / Cai01.09.09.M.Sc.2016.Sh.I In vitro comparative study of dimensional changes of polyether & additional silicone impression materials for bounded partially edentulous / Cai01.09.09.M.Sc.2016.Sh.I In vitro comparative study of dimensional changes of polyether & additional silicone impression materials for bounded partially edentulous /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

The aim of the present study is to evaluate the marginal accuracy and fracture resistance of zirconia restoration using two finish line types, two veneering techniques and two margin designs. A total of 40 zirconia crowns were used. The samples were divided into 2 groups and two sub groups and two sub division groups; according to two finish line types, two veneering technique and two margin designs. Two specially constructed metal dies were machine milled representing upper first premolar preparation to receive all-ceramic restoration. The first die had deep chamfer finish line, while the second die had shoulder finish line. A total number of forty zirconia copings were constructed. They were divided in two main groups, 20 samples each. Group (A): Samples with deep chamfer finish line. Group (B): Samples with shoulder finish line. Samples of each group were subdivided into two equal subgroups (10 samples) according to the technique of veneer application. Sub group }: Veneering material was applied using layering technique. Sub group {u2161}: Veneering material was applied using press on technique. Each subgroup was further sub divided into two equal sub divisions (5 samples each) according to the type of the material at the restoration margin. Sub division }: Coping margin was made up of zirconia material (zirconia margin). Sub division {u2161}: Coping margin was cutback by 1 mm and IPS e.max was added cut back margin (e.max margin). Zirconia copings were constructed on prefabricated metal dies using the Zirkonzahn CAD/CAM system; Also CAD wax was constructed for press on technique with the same system. Either layering or pressing veneering techniques were performed according to manufactures instructions. Marginal accuracy and fracture resistance were used as testing methods. Scanning electron microscope was used to detect the mode of failure

Issued also as CD

There are no comments on this title.

to post a comment.