header
Local cover image
Local cover image
Image from OpenLibrary

Evaluation of patients satisfaction of obturator with attachment versus conventional obturator in treatment of unilateral maxillectomy : A randomized clinical trial / Mohammed Yehia Sharaf ; Supervised Samira Ibrahim Ibrahim , Ashraf Emil Eskander

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohammed Yehia Sharaf , 2017Description: 188 P. : charts , facimiles ; 25cmOther title:
  • تقيم درجه رضاء المرضى فى السدات الفكيه العلويه المثبته بالوصلات مقارنه بالسدات المثبته بمشابك فى علاج حالات بتر الفك العلوى فى جانب واحد [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine- Department of Prosthodontic Summary: This study was carried out to evaluate the effect of attachment retained obturator versus clasp retained obturator on the patients satisfaction and the supporting structures in the treatment of unilateral maxillectomy . Fourteen patients (eight females and six males) were selected from the Outpatient Clinic, Prosthodontics Department , Maxillofacial Prosthodontics Unit, Faculty of Oral and Dental Medicine Cairo University or referred from The National Cancer Institute. All patients were with unilateral maxillectomy . Patients were divided randomly into two equal groups each of seven patients (four females and three males) where each patient received an obturator as follows: Patients of the first group received attachment retained obturators. Patients of the second group received clasp retained obturators. Quality of life evaluation (patient satisfaction) was recorded at one month of prosthesis insertion , after three and nine months later by using two scales a) Obturator Functioning Scale b)The European Organization for Research and Treatment of Cancer Head and Neck 35 (cancer-specific module) It was shown that the patient satisfaction scale was statistically significantly higher in clasp retained obturator group compared to attachment retained obturatori.e(the patient of attachment group were more satisfied than the clasp group) Radiographic changes were recorded at the time of prosthesis insertion , after three six, nine months later for marginal bone height and density changes around the anterior and posterior abutments. It was shown that the changes in the marginal bone height measurements after nine months of prosthesis insertion were statistically significantly higher in the clasp group compared to the attachment . And also, the changes in bone density measurements were statistically significantly higher in the attachment group compared to the clasp between both groups along the study period
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2017.Mo.E (Browse shelf(Opens below)) Not for loan 01010110074856000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2017.Mo.E (Browse shelf(Opens below)) 74856.CD Not for loan 01020110074856000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.Ph.D.2017.Mo.E The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر / Cai01.09.09.Ph.D.2017.Mo.E The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر / Cai01.09.09.Ph.D.2017.Mo.E Evaluation of patients satisfaction of obturator with attachment versus conventional obturator in treatment of unilateral maxillectomy : A randomized clinical trial / Cai01.09.09.Ph.D.2017.Mo.E Evaluation of patients satisfaction of obturator with attachment versus conventional obturator in treatment of unilateral maxillectomy : A randomized clinical trial / Cai01.09.09.Ph.D.2017.Mo.I Impact of CAD-CAM designed telescopic crown retainers versus conventional clasps on the patient satisfaction and biting force for patient restored by mandibular distal extension removable partial dentures : Randomized Clinical Trial / Cai01.09.09.Ph.D.2017.Mo.I Impact of CAD-CAM designed telescopic crown retainers versus conventional clasps on the patient satisfaction and biting force for patient restored by mandibular distal extension removable partial dentures : Randomized Clinical Trial / Cai01.09.09.Ph.D.2017.Mo.I Influence of cleaning solution (Ivoclean) on the retention of saliva contaminated zirconia based copings using a novel bioactive cement (ceramir) : In-vitro study /

Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine- Department of Prosthodontic

This study was carried out to evaluate the effect of attachment retained obturator versus clasp retained obturator on the patients satisfaction and the supporting structures in the treatment of unilateral maxillectomy . Fourteen patients (eight females and six males) were selected from the Outpatient Clinic, Prosthodontics Department , Maxillofacial Prosthodontics Unit, Faculty of Oral and Dental Medicine Cairo University or referred from The National Cancer Institute. All patients were with unilateral maxillectomy . Patients were divided randomly into two equal groups each of seven patients (four females and three males) where each patient received an obturator as follows: Patients of the first group received attachment retained obturators. Patients of the second group received clasp retained obturators. Quality of life evaluation (patient satisfaction) was recorded at one month of prosthesis insertion , after three and nine months later by using two scales a) Obturator Functioning Scale b)The European Organization for Research and Treatment of Cancer Head and Neck 35 (cancer-specific module) It was shown that the patient satisfaction scale was statistically significantly higher in clasp retained obturator group compared to attachment retained obturatori.e(the patient of attachment group were more satisfied than the clasp group) Radiographic changes were recorded at the time of prosthesis insertion , after three six, nine months later for marginal bone height and density changes around the anterior and posterior abutments. It was shown that the changes in the marginal bone height measurements after nine months of prosthesis insertion were statistically significantly higher in the clasp group compared to the attachment . And also, the changes in bone density measurements were statistically significantly higher in the attachment group compared to the clasp between both groups along the study period

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image