Patient{u2019}s contentment and accuracy of transferring orthodontic attachments between two indirect bonding techniques : a randomized controlled trial / Nada Mohammad Salem Mohammad ; Supervised Mohamed Amgad Kaddah , Mona Mohamed Salah Fayed , Fady Hussein Fahim
Material type:
- مدى رضا المريض و دقة نقل الملحقات التقويمية باستخدام طريقتي لصق غير مباشر : دراسة سريرية عشوائية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.06.M.Sc.2017.Na.P (Browse shelf(Opens below)) | Not for loan | 01010110075170000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.06.M.Sc.2017.Na.P (Browse shelf(Opens below)) | 75170.CD | Not for loan | 01020110075170000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Orthodontics
Aim of the study: To compare the two used methods of indirect bonding regarding the patient{u2019}s satisfaction during the bonding procedure. To compare the accuracy of transferring orthodontic attachments in all three planes of space by two indirect bonding widely used techniques, using means of 3 dimensional (3D) scanning and superimposition ,and to record the failure rate of the orthodontic tubes of posterior teeth over a four months period. Materials and methods: A randomized controlled trial was performed, 21 subject with fully erupted upper and lower first and second permanent molars showing no signs of enamel defects or signs of gingival inflammation were recruited in this study. 168 attachments were bonded to first and second molar teeth. A questionnaire was given to each subject to measure their satisfaction towards the used indirect bonding trays. After placement of molar tubes on the working model, the model was scanned with a desktop scanner, and the preoperative STL model was saved, a Vinyl polysiloxane VPS tray and a soft vacuum-formed tray were fabricated, one on each half of the working model, then the tubes were transferred to the patient{u2019}s dentition, a secondary impression was then made and poured, and the post-transfer model was then scanned with the same desktop scanner and the post-transfer STL model was saved. By using the Geomagic qualify version 12, the 2 STL models were superimposed and the deviations were detected for 3 linear measurements (mesio-disal, occluso-gingival, bucco-lingual) and 3 angular measurements (tip, torque, rotation). The debonded tubes were recorded for a follow up duration of 4 months
Issued also as CD
There are no comments on this title.