A methodology for photovoltaic integration in retrofitting office buildingsin Egypt / Salwa Abdelmonem Elgindi ; Supervised Ahmed Reda Abdin , Ayman Hassan Ahmed , Ehab Farouk Rached
Material type:
- منهج لاعادة تأهيل مبانى المكاتب باستخدام الخلايا الكهروضوئية في مصر [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.02.Ph.D.2018.Sa.M (Browse shelf(Opens below)) | Not for loan | 01010110075688000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.02.Ph.D.2018.Sa.M (Browse shelf(Opens below)) | 75688.CD | Not for loan | 01020110075688000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.02.Ph.D.2018.No.P The potential effect of urban image on city branding / | Cai01.13.02.Ph.D.2018.No.P Public places for happiness: Towards a model for designing urban public places / | Cai01.13.02.Ph.D.2018.No.P Public places for happiness: Towards a model for designing urban public places / | Cai01.13.02.Ph.D.2018.Sa.M A methodology for photovoltaic integration in retrofitting office buildingsin Egypt / | Cai01.13.02.Ph.D.2018.Sa.M A methodology for photovoltaic integration in retrofitting office buildingsin Egypt / | Cai01.13.02.Ph.D.2018.Sh.A An approach for ventilated double skin facade through a parametric movement intervention / | Cai01.13.02.Ph.D.2018.Sh.A An approach for ventilated double skin facade through a parametric movement intervention / |
Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Architectural Engineering
This research proposes an integrated design methodology to reduce the energy consumption and optimize the Photovoltaic (PV) integration in energy retrofit of an office building by minimizing the life cycle cost taking into account the initial cost and incentives, energy benefits, as well as looking at the overall environmental impact. The research aims at improving the energy efficiency of the existing building stock by upgradingthe building envelope through carrying out various retrofit measures and the integration of photovoltaics. The objective is to reach the optimal combination of applying energy efficiency measures and PV integration in an energy efficient retrofit. A systematicapproach forthe proper selection of the best retrofit options for existing office buildings is presented. This approach introduces methods to evaluate the improvement in the thermal performance of the building , quantify the energy benefits and environmental benefits achieved and assess the economic impact
Issued also as CD
There are no comments on this title.