header
Local cover image
Local cover image
Image from OpenLibrary

The effect of lean body mass evaluated by musculoskeletal ultrasound on resting energy expenditure measured by indirect calorimetry : Prospective observational study / Mohamed Abdelghany Ali ; Supervised Walid Ibrahim Hamimy , Ahmed Mohamed Mukhtar, Islam Ayman Shawky

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohamed Abdelghany Ali , 2018Description: 48 P. : charts , facsimiles ; 25cmOther title:
  • تأثير قياس كتلة الجسم الخالية من الدهون عن طريق السونار العضلى على الطاقة المستهلكه اثناء الراحه عن طريق جهاز قياس السعرات الحرارية الغير مباشر [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Anaesthesia Summary: All consecutive patients that were admitted to intensive care unit (ICU) and required mechanical ventilation were enrolled in the study. Bed side ultrasound was used to measure muscle layer thickness (MLT) and cardiac output (CO). MLT was measured within 24 of ICU admission. Two measurements of MLT were made at two sites; mid-upper arm and thigh anteriorly using linear array transducer. MLT was determined and summed up. Stroke volume was obtained by placing pulsed wave Doppler in the middle of left ventricular outflow tract using phased array transducer. CO was calculated by multiplying SV and heart rate. REE was calculated using indirect calorimetry via metabolic module on General Electric ventilator (Engstrom Carestation and Carescape R860, GE Health care, USA). A multiple regression analysis was applied to a set of independent variables to develop the predictive equation of REE
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.01.Ph.D.2018.Mo.E (Browse shelf(Opens below)) Not for loan 01010110076280000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.01.Ph.D.2018.Mo.E (Browse shelf(Opens below)) 76280.CD Not for loan 01020110076280000

Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Anaesthesia

All consecutive patients that were admitted to intensive care unit (ICU) and required mechanical ventilation were enrolled in the study. Bed side ultrasound was used to measure muscle layer thickness (MLT) and cardiac output (CO). MLT was measured within 24 of ICU admission. Two measurements of MLT were made at two sites; mid-upper arm and thigh anteriorly using linear array transducer. MLT was determined and summed up. Stroke volume was obtained by placing pulsed wave Doppler in the middle of left ventricular outflow tract using phased array transducer. CO was calculated by multiplying SV and heart rate. REE was calculated using indirect calorimetry via metabolic module on General Electric ventilator (Engstrom Carestation and Carescape R860, GE Health care, USA). A multiple regression analysis was applied to a set of independent variables to develop the predictive equation of REE

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image