Effect of different elbow joint angles on ulnar nerve conduction velocity among computer users / Doaa Yasser Abdelfattah ; Supervised Mohamed Hussein Elgendy , Ibrahim Mohamed Ibrahim
Material type: TextLanguage: English Publication details: Cairo : Doaa Yasser Abdelfattah , 2018Description: 71 P. : charts , facsimiles ; 25cmOther title:- تأثير زوايا مختلفة لمفصل الكوع على سرعة توصيل العصب الزندى فى مستخدمى الكمبيوتر [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.21.09.M.Sc.2018.Do.E (Browse shelf(Opens below)) | Not for loan | 01010110077210000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.21.09.M.Sc.2018.Do.E (Browse shelf(Opens below)) | 77210.CD | Not for loan | 01020110077210000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Sciences
Background: long duration of computer work could result in pain and weakness associated with decreased nerve conduction velocities (NCV) of peripheral nerves. Purpose: To identify the ulnar nerve conduction velocity at different elbow joint angles in computer users. To compare across elbow ulnar nerve motor conduction velocity MNCV between the limited and extensive computer users. To identify the ideal elbow positions for computer users during work. Design of the study: Ex post facto design. Subjects: Fifty computer users from both sexes, their age ranged from 20 to 40 years. They were assigned into two equal study groups. Group A consisted of limited computer operators who worked a maximum of 2 hours per day while Group B consisted of extensive computer operators who worked on the computer for a minimum of 6 hours per day as a part of regular work for at least 1 year. Subjects were using the computer devices with a position of elbow flexion ranged from 90 to 120 degrees. Methods: NCV was used for measuring ulnar MNCV across elbow at different angles (0{u00BA}, 45{u00BA}, 90{u00BA}, 120{u00BA}) in both groups. Results: Mixed design ANOVA was used and revealed that there was a significant difference in ulnar nerve motor conduction velocity at zero elbow flexion (elbow extension) compared with other positions(45, 90, and 120 degrees of elbow flexion) in both groups, as well there was a significant difference in nerve motor conduction velocity at 45 degrees of elbow flexion than 90 and 120 degrees in both groups
Issued also as CD
There are no comments on this title.