header
Image from OpenLibrary

Design and modeling of medical linear accelerators using the geant 4/GATE platform / Soad Mostafa Mohammed Hozayen ; Supervised Hoda Abou-Shady , Hassan Fathy Ibrahim

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Soad Mostafa Mohammed Hozayen , 2018Description: 160 P. : facsimiles ; 25cmOther title:
  • Geant4/GATE تصميم و نمذجة المعجلات الخطية الطبية باستخدام نظام [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics Summary: The aim of this research is to investigate the use of GATE, the monte Carlo simulation application based on Geant 4 toolkit to estimate the percent depth doses and dose Off-Axis Ratios of a novel medical linear accelerator for photon mode field sizes 5{u00D7}5, 10{u00D7}10, 20{u00D7}20, 30{u00D7}30 and 40{u00D7}40 cm² and also for electron mode field sizes 5{u00D7}5, 10{u00D7}10, 15{u00D7}15 and 20{u00D7}20 cm² at the isocenter. A model for the 60{u00D7}50{u00D7}40.75 cm³ PTW MP3 water phantom was used in the simulations. Firstly, verification of the dose calculations of two medical linacs: Siemens ONCOR for field sizes 10{u00D7}10, 20{u00D7}20 and 30{u00D7}30 cm² and varian 600C for field sizes 3{u00D7}3, 6{u00D7}6 and 9.8{u00D7}9.8 cm² using 6 MeV electron beam, were confirmed
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.20.M.Sc.2018.So.D (Browse shelf(Opens below)) Not for loan 01010110077253000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.20.M.Sc.2018.So.D (Browse shelf(Opens below)) 77253.CD Not for loan 01020110077253000

Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics

The aim of this research is to investigate the use of GATE, the monte Carlo simulation application based on Geant 4 toolkit to estimate the percent depth doses and dose Off-Axis Ratios of a novel medical linear accelerator for photon mode field sizes 5{u00D7}5, 10{u00D7}10, 20{u00D7}20, 30{u00D7}30 and 40{u00D7}40 cm² and also for electron mode field sizes 5{u00D7}5, 10{u00D7}10, 15{u00D7}15 and 20{u00D7}20 cm² at the isocenter. A model for the 60{u00D7}50{u00D7}40.75 cm³ PTW MP3 water phantom was used in the simulations. Firstly, verification of the dose calculations of two medical linacs: Siemens ONCOR for field sizes 10{u00D7}10, 20{u00D7}20 and 30{u00D7}30 cm² and varian 600C for field sizes 3{u00D7}3, 6{u00D7}6 and 9.8{u00D7}9.8 cm² using 6 MeV electron beam, were confirmed

Issued also as CD

There are no comments on this title.

to post a comment.