Accuracy of linear measurements using ultra low dose CBCT protocol compared to standard CBCT protocol : Diagnostic accuracy study : in vitro study / Esraa Khairy Morsy ; Supervisd Sahar Hosny Eldessouky , Nashwa Salah Mohamed , Enas Anter Abdelghafar

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Esraa Khairy Morsy , 2018Description: 169 P. : charts , facsimiles ; 25cmOther title:
  • دقة القياسات الخطية باستخدام بروتوكول الجرعة فائقة الانخفاض مقارنةً بالبروتوكول الاعتيادي للأشعة المقطعية بالحاسوب مخروطية الشعاع : دراسة دقة تشخيصية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis) Summary: The current study was conducted on dry human skulls to evaluate the accuracy of CBCT linear measurements obtained by both standard and ULD protocols and to the compare the measurement error of 2D MPR and 3D VR images obtained by both protocols.Twenty-three anatomical landmarks were marked on each of the sixteen included skulls, gutta percha pieces were glued on the marked anatomical landmarks, and then fourteen linear measurements were taken between them using a digital caliper. These direct linear measurements were considered as the gold standard. The skulls included in the study were covered with twelve layers of pink modeling wax to simulate soft tissue attenuation, then were scanned using Planmeca Promax 3D Mid CBCT machine with two different scan protocols -the standard and ULD one-.The CBCT raw data was imported to a third party software (In Vivo 5), and the same fourteen linear measurements were taken on both 3D VR images and 2D MPR orthogonal images. Superimposition of both standard and ULD CBCT images was performed for standardization of measurements on the 2D MPR images
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.05.M.Sc.2018.Es.A (Browse shelf(Opens below)) Not for loan 01010110078143000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.05.M.Sc.2018.Es.A (Browse shelf(Opens below)) 78143.CD Not for loan 01020110078143000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.05.M.Sc.2018.As.D Diagnostic accuracy of (planmeca pro max 3D Mid) CBCT unit in detection of second mesiobuccal root canal in maxillary molars by using different voxel sizes : Diagnostic accuracy study / Cai01.09.05.M.Sc.2018.As.U Ultra-Low dose CBCT Protocol in assessment of simulated external root resorption in mandibular teeth : Preclinical study / Cai01.09.05.M.Sc.2018.As.U Ultra-Low dose CBCT Protocol in assessment of simulated external root resorption in mandibular teeth : Preclinical study / Cai01.09.05.M.Sc.2018.Es.A Accuracy of linear measurements using ultra low dose CBCT protocol compared to standard CBCT protocol : Diagnostic accuracy study : in vitro study / Cai01.09.05.M.Sc.2018.Es.A Accuracy of linear measurements using ultra low dose CBCT protocol compared to standard CBCT protocol : Diagnostic accuracy study : in vitro study / Cai01.09.05.M.Sc.2018.Ja.A Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements : Pre-clinical study , Cai01.09.05.M.Sc.2018.Ja.A Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements : Pre-clinical study ,

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)

The current study was conducted on dry human skulls to evaluate the accuracy of CBCT linear measurements obtained by both standard and ULD protocols and to the compare the measurement error of 2D MPR and 3D VR images obtained by both protocols.Twenty-three anatomical landmarks were marked on each of the sixteen included skulls, gutta percha pieces were glued on the marked anatomical landmarks, and then fourteen linear measurements were taken between them using a digital caliper. These direct linear measurements were considered as the gold standard. The skulls included in the study were covered with twelve layers of pink modeling wax to simulate soft tissue attenuation, then were scanned using Planmeca Promax 3D Mid CBCT machine with two different scan protocols -the standard and ULD one-.The CBCT raw data was imported to a third party software (In Vivo 5), and the same fourteen linear measurements were taken on both 3D VR images and 2D MPR orthogonal images. Superimposition of both standard and ULD CBCT images was performed for standardization of measurements on the 2D MPR images