Numerical simulation of smoke management system insprinklered car parks / Dalia Essam Eldin Khalil ; Supervised Samy Mourad Morcos , Mohamed Mahmoud Ali Hassan , Ahmed A. Fahim

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Dalia Essam Eldin Khalil , 2019Description: 127 P. : charts , facsimiles ; 30cmOther title:
  • محاكاه عددية للتحكم فى أدخنة الحرائق داخل جراجات السيارات المزودة بأنظمة اطفاء ألى [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering Summary: The following thesis aims to study the effect of sprinklers activation on the fire induced smoke behaviour and the interaction of water particles with the smoke layer by using Fire Dynamic Simulator (FDS 6.5.3). It was found that the sprinkler activation drastically decreased the visibility at occupant{u2019}s level. The sprinklers water particles when activated dragged the smoke layer downwards due to its momentum.Increasing the ceiling height to 3.5 m in case of impulse ventilation system and 3.2 m in case of ducted system and the sprinkler operating pressure to a minimum of 4bar may help reduce the problem
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.11.Ph.D.2019.Da.N (Browse shelf(Opens below)) Not for loan 01010110078599000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.11.Ph.D.2019.Da.N (Browse shelf(Opens below)) 78599.CD Not for loan 01020110078599000

Thesis (Ph.D.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering

The following thesis aims to study the effect of sprinklers activation on the fire induced smoke behaviour and the interaction of water particles with the smoke layer by using Fire Dynamic Simulator (FDS 6.5.3). It was found that the sprinkler activation drastically decreased the visibility at occupant{u2019}s level. The sprinklers water particles when activated dragged the smoke layer downwards due to its momentum.Increasing the ceiling height to 3.5 m in case of impulse ventilation system and 3.2 m in case of ducted system and the sprinkler operating pressure to a minimum of 4bar may help reduce the problem