Retention of saddle lock esthetic clasp versus equipoise clasp in Kennedy class III removable partial dentures : In-vitro study / Mohammed Essam Khalill ; Supervised Amal Fathy Kaddah , Ahmed Emad Fayyad

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohammed Essam Khalill , 2017Description: 81 P. : charts , facsimiles ; 25cmOther title:
  • مقارنه قوه الاستبقاء للمشابك الجماليه الخاصه بتثبيت السرج ومشابك التوازن لحالات كيندى الفصل الثالث فى الطقم الجزئى المتحرك : دراسه معمليه [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: This study was conducted for acrylic model with class III modification one to investigate and compare the retentive force of the Equipoise clasps and the Saddle lock clasps (as control group) by using digital force meter.The frameworks of the bilateral partial dentures for each clasp design were constructed on the acrylic model. The 11 framework of each clasp design were from cobalt-chromium (Co-Cr) alloy.The undercut of 0.01 inch was the same for all clasps.Results of this study showed that equipoise clasp design of mean retentive force (61.06 ± 3.52 N) had a significant higher retentive force than Saddle lock design of mean retentive force (44.54 ± 5.88 N). both clasp engage 0.01 undercut and constructed from the same material CO-CR alloy
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2017.Mo.R (Browse shelf(Opens below)) Not for loan 01010110079202000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2017.Mo.R (Browse shelf(Opens below)) 79202.CD Not for loan 01020110079202000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.M.Sc.2017.Mo.I Influence of post relining on the retention of Macro-lock Illusion X-RO and RelyX smooth fiber posts cemented by self adhesive resin cement : In-vitro study / Cai01.09.09.M.Sc.2017.Mo.M Microbiological comparative study between single maxillary denture fabricated from rapid heat cure acrylic resin material and conventional acrylic resin material modified by titanium dioxide nanoparticles : A randomized clinical trial / Cai01.09.09.M.Sc.2017.Mo.M Microbiological comparative study between single maxillary denture fabricated from rapid heat cure acrylic resin material and conventional acrylic resin material modified by titanium dioxide nanoparticles : A randomized clinical trial / Cai01.09.09.M.Sc.2017.Mo.R Retention of saddle lock esthetic clasp versus equipoise clasp in Kennedy class III removable partial dentures : In-vitro study / Cai01.09.09.M.Sc.2017.Mo.R Retention of saddle lock esthetic clasp versus equipoise clasp in Kennedy class III removable partial dentures : In-vitro study / Cai01.09.09.M.Sc.2017.Mo.R Retention of esthetic saddle lock clasp versus conventional clasp in bounded removable partial denture cases / Cai01.09.09.M.Sc.2017.Mo.R Retention of esthetic saddle lock clasp versus conventional clasp in bounded removable partial denture cases /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

This study was conducted for acrylic model with class III modification one to investigate and compare the retentive force of the Equipoise clasps and the Saddle lock clasps (as control group) by using digital force meter.The frameworks of the bilateral partial dentures for each clasp design were constructed on the acrylic model. The 11 framework of each clasp design were from cobalt-chromium (Co-Cr) alloy.The undercut of 0.01 inch was the same for all clasps.Results of this study showed that equipoise clasp design of mean retentive force (61.06 ± 3.52 N) had a significant higher retentive force than Saddle lock design of mean retentive force (44.54 ± 5.88 N). both clasp engage 0.01 undercut and constructed from the same material CO-CR alloy