Maintenance and cost effectiveness of cendres metaux locator (CM-LOC) resin matrix versus ball nylon matrix attachment retaining single implant mandibular complete overdentures : A randomized clinical trial / Amr Ahmed Naguib ; Supervised Ashraf Abdelmonaem , Nada Sherin Elkhourazaty
Material type: TextLanguage: English Publication details: Cairo : Amr Ahmed Naguib , 2019Description: 138 P. : charts , facsimiles ; 25cmOther title:- والرابط الكروى على الزرعه من حيث الصيانة و التكلفة في الاطقم السفلية المحملة على زرعة واحدة CM-LOC المقارنة بين رابط ال : تجربة سريرية عشوائية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.Ph.D.2019.Am.M (Browse shelf(Opens below)) | Not for loan | 01010110080227000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.Ph.D.2019.Am.M (Browse shelf(Opens below)) | 80227.CD | Not for loan | 01020110080227000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
52 completely edentulous patients were selected from 138 patients examined in the outpatient clinic of the Removable Prosthodontics Department, Faculty of Dentistry Cairo University, after thorough examination and receiving a complete denture.The selected patients were divided into two groups. Group A received upper complete denture and lower single implant mandibular overdenture retained by CM-LOC attachment.Group B received upper complete denture and lower single implant mandibular overdenture retained by ball attachment.Patients were periodically examined every 3 months starting from starting pick up procedure till 1 year follow up. Prosthetic maintenance and cost analysis data were saved in excel sheets after each follow up visit. In terms of prosthetic maintenance the CM-LOC group rate of change of matrix, relining of lower denture, fracture of lower denture was higher than the ball group rate. On the other hand, the rate of fracture of the upper group was higher in the ball group. The rate of all other prosthetic maintenance events was nearly the same. The number of the total prosthetic maintenance events was similar in both groups. In terms of cost analysis, the CM-LOC group was higher than the ball group in both the initial cost and after care cost. The total cost of the CM-LOC attachment was 2.22 times more than the ball attachment
Issued also as CD
There are no comments on this title.