Evaluation of chewing efficiency of metal reinforced polyamide denture base in comparison to conventional heat cured acrylic resin denture base for mandibular complete denture : A randomized clinical trial / Mahmoud Abdallah Abdelmottaleb ; Supervised Amal Fathy Kaddah , Mostafa Helmy
Material type:
- دراسة لتقييم كفاءة المضغ للطقم الكلى السفلى المصنوع من البولى أميد المقوى بالمعدن مقارنة بالمصنوع من الاكريليك [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2019.Ma.E (Browse shelf(Opens below)) | Not for loan | 01010110080277000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2019.Ma.E (Browse shelf(Opens below)) | 80277.CD | Not for loan | 01020110080277000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
Aim of the study: In vivo study was conducted to compare the effect of two different denture base materials (conventional heat cure acrylic resin and metal reinforced polyamide) on the chewing efficiency of the mandibular complete denture. Materials and methods: Thirty eight patients with completely edentulous maxilla were randomly selected according to inclusion and exclusion criteria, primary impressions were made using irreversible hydrocolloid, secondary impressions were made using green stick compound as a border molding material and Zinc oxide/eugenol as a final wash impression material then the master casts were duplicated using duplicating silicone, group I (conventional heat cure acrylic resin). Group II (metal reinforced polyamide dentures) construction of the metal framework. The design of the framework was done then traced on the refractory cast followed by spruing, investing, burning out and casting of the metal framework with the casted metal posts attached to it. In a special flask designed for injection-molding technique, dewaxing was carried by placing flasks in boiling water for 3 to 5 minutes to soften the wax.) were processed in boiling water for 20 minutes, each group received the dentures; then chewing efficiency was measured using Sieve device
Issued also as CD
There are no comments on this title.