False trips in gas power plant due to transient voltage variation / Mahmoud Ismail Mehanna ; Supervised Essam Eldin M. Aboulzahab , Mahmoud Ibrahim Gilany
Material type:
- الفصل الخاطئ فى محطات التوليد الغازية نتيجة التذبذب اللحظى فى الجهد [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2019.Ma.F (Browse shelf(Opens below)) | Not for loan | 01010110080281000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2019.Ma.F (Browse shelf(Opens below)) | 80281.CD | Not for loan | 01020110080281000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.07.M.Sc.2019.Di.M Modeling and control of photovoltaic connected to grid based on advanced evolutionary techniques / | Cai01.13.07.M.Sc.2019.Eh.S A study on the impact of introducing utility scale pv power plants to the Egyptian Grid In Benban, Aswan / | Cai01.13.07.M.Sc.2019.Eh.S A study on the impact of introducing utility scale pv power plants to the Egyptian Grid In Benban, Aswan / | Cai01.13.07.M.Sc.2019.Ma.F False trips in gas power plant due to transient voltage variation / | Cai01.13.07.M.Sc.2019.Ma.F False trips in gas power plant due to transient voltage variation / | Cai01.13.07.M.Sc.2019.Ma.S Stereo and mono vision sorting of known objects and grasping using industrial robot arm / | Cai01.13.07.M.Sc.2019.Ma.S Stereo and mono vision sorting of known objects and grasping using industrial robot arm / |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
The sudden isolation of a large combined cycle power plant in Alburullus, Kafr Elsheikh city, Egypt with a capacity of 4800 MW will lead to a defect in the electric grid stability. This sudden isolation occurs due to Trip important sensitive loads in the Gas station of this plant (Fuel gas compressors and auxiliary air compressor). This thesis presents some of the published researches for power conditioning devices used for compensating the voltage fluctuation problem. (DVR) was selected to monitor the source voltage of these sensitive loads and compare it with the reference voltage. If any voltage drop is detected, this value is injected into the load side. MATLAB/Simulink program is used to verify the effectiveness of this device in the compensation of the voltage sag with these loads in a duration less than 10msec. which is less than the trip setting of the load C.B
Issued also as CD
There are no comments on this title.