False trips in gas power plant due to transient voltage variation / Mahmoud Ismail Mehanna ; Supervised Essam Eldin M. Aboulzahab , Mahmoud Ibrahim Gilany

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mahmoud Ismail Mehanna , 2019Description: 81 P. ; 30cmOther title:
  • الفصل الخاطئ فى محطات التوليد الغازية نتيجة التذبذب اللحظى فى الجهد [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines Summary: The sudden isolation of a large combined cycle power plant in Alburullus, Kafr Elsheikh city, Egypt with a capacity of 4800 MW will lead to a defect in the electric grid stability. This sudden isolation occurs due to Trip important sensitive loads in the Gas station of this plant (Fuel gas compressors and auxiliary air compressor). This thesis presents some of the published researches for power conditioning devices used for compensating the voltage fluctuation problem. (DVR) was selected to monitor the source voltage of these sensitive loads and compare it with the reference voltage. If any voltage drop is detected, this value is injected into the load side. MATLAB/Simulink program is used to verify the effectiveness of this device in the compensation of the voltage sag with these loads in a duration less than 10msec. which is less than the trip setting of the load C.B
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2019.Ma.F (Browse shelf(Opens below)) Not for loan 01010110080281000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2019.Ma.F (Browse shelf(Opens below)) 80281.CD Not for loan 01020110080281000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines

The sudden isolation of a large combined cycle power plant in Alburullus, Kafr Elsheikh city, Egypt with a capacity of 4800 MW will lead to a defect in the electric grid stability. This sudden isolation occurs due to Trip important sensitive loads in the Gas station of this plant (Fuel gas compressors and auxiliary air compressor). This thesis presents some of the published researches for power conditioning devices used for compensating the voltage fluctuation problem. (DVR) was selected to monitor the source voltage of these sensitive loads and compare it with the reference voltage. If any voltage drop is detected, this value is injected into the load side. MATLAB/Simulink program is used to verify the effectiveness of this device in the compensation of the voltage sag with these loads in a duration less than 10msec. which is less than the trip setting of the load C.B