header
Local cover image
Local cover image
Image from OpenLibrary

Chairside time and bond failure of non-custom versus custom base orthodontic attachments during indirect bonding : A randomized clinical trial / Mohamed Saied Mahmoud ; Supervised Fatma Abdou Abdelsayed , Amany Hassan Abdelghany , May Hamdy Aboulfotouh

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohamed Saied Mahmoud , 2019Description: 110 P. : charts , facsimiles ; 252cmOther title:
  • مدة المعالجه و فشل الالتصاق للقاعده الغير معده مسبقا او القاعده المعده مسبقا للحاصرات التقويميه خلال اللصق الغير مباشر : دراسه سريريه عشوائيه [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Orthodontics Summary: A randomized clinical trial (split-mouth design) was done to compare between the two techniques, 6 patients were enrolled in the study with full sound permanent set of maxillary dentition to allow bonding of 84 orthodontic attachments. The sample size was 84 teeth divided into two equal groups. Group I was the intervention group (non-custom base) while group II was the control group (custom base). Impressions were taken to fabricate the working models; then orthodontic attachments were either bonded with water soluble glue representing the intervention group or bonded with composite resin adhesive representing the control group. The orthodontic attachments were bonded to the working model according to the horizontal and vertical reference lines used in the indirect bonding technique. Then, the working model was sprayed with titanium dioxide and scanned with an intraoral scanner to make and STL file of the working model. The transfer tray (vacuum formed soft tray 1.5 mm thickness) was then fabricated in order to carry the orthodontic attachments to the maxillary teeth. The attachments were then transferred to the patient{u2019}s dentition where each quadrant represented either non-custom or custom base technique. The chairside time of the clinical procedure was recorded using a stop watch. After tray detachment, the number of failed attachments were recorded and re-bonded again using the same transfer tray
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.06.M.Sc.2019.Mo.C (Browse shelf(Opens below)) Not for loan 01010110080485000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.06.M.Sc.2019.Mo.C (Browse shelf(Opens below)) 80485.CD Not for loan 01020110080485000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.06.M.Sc.2019.Ma.E Evaluation of casein phosphopeptides-amorphous calcium phosphate (CPP-ACP) prophylactic effect on enamel surface during orthodontic treatment : A randomized controlled trial / Cai01.09.06.M.Sc.2019.Mo.C Chairside time and accuracy of indirect bonding of orthodontic attachments using double versus single transfer tray (split mouth design) : A randomized controlled trial / Cai01.09.06.M.Sc.2019.Mo.C Chairside time and accuracy of indirect bonding of orthodontic attachments using double versus single transfer tray (split mouth design) : A randomized controlled trial / Cai01.09.06.M.Sc.2019.Mo.C Chairside time and bond failure of non-custom versus custom base orthodontic attachments during indirect bonding : A randomized clinical trial / Cai01.09.06.M.Sc.2019.Mo.C Chairside time and bond failure of non-custom versus custom base orthodontic attachments during indirect bonding : A randomized clinical trial / Cai01.09.06.M.Sc.2019.Mo.D Distribution of ABO blood groups in relation to cleft lip and/or palate : Cross sectional - Risk oriented study / Cai01.09.06.M.Sc.2019.Mo.D Distribution of ABO blood groups in relation to cleft lip and/or palate : Cross sectional - Risk oriented study /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Orthodontics

A randomized clinical trial (split-mouth design) was done to compare between the two techniques, 6 patients were enrolled in the study with full sound permanent set of maxillary dentition to allow bonding of 84 orthodontic attachments. The sample size was 84 teeth divided into two equal groups. Group I was the intervention group (non-custom base) while group II was the control group (custom base). Impressions were taken to fabricate the working models; then orthodontic attachments were either bonded with water soluble glue representing the intervention group or bonded with composite resin adhesive representing the control group. The orthodontic attachments were bonded to the working model according to the horizontal and vertical reference lines used in the indirect bonding technique. Then, the working model was sprayed with titanium dioxide and scanned with an intraoral scanner to make and STL file of the working model. The transfer tray (vacuum formed soft tray 1.5 mm thickness) was then fabricated in order to carry the orthodontic attachments to the maxillary teeth. The attachments were then transferred to the patient{u2019}s dentition where each quadrant represented either non-custom or custom base technique. The chairside time of the clinical procedure was recorded using a stop watch. After tray detachment, the number of failed attachments were recorded and re-bonded again using the same transfer tray

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image